Bosch ICP-CC488 User Manual

Page of 118
ICP-CC488 | Installation Guide | 1.0  
Introduction 
EN | 9 
 
 
Bosch Security Systems, Inc. | 12/08 | F01U089457-02 
 
1.2 Quick 
Start 
The following steps allow you to use the ICP-CC488 
Control Panel with factory default values. The default 
values allow the control panel to communicate in the 
Contact ID format. If you are not familiar with 
programming the control panels, read the 
information in Section 7.0 Programming before starting 
the installation. 
After all wiring is complete, connect the AC plug 
pack to the control panel. 
Both the MAINS and AWAY indicators are lit.  
The MAINS indicator lights to indicate the AC 
MAINS supply is connected.  
The AWAY indicator lights to signify the system 
is armed in AWAY Mode.  
If any 24-Hour zones are unsealed when you 
power up the system, the Siren, Strobe, and Bell 
Outputs are activated into alarm and the 
corresponding zone indicator flashes. 
Enter the default Master Code (2580) and press 
[AWAY] to disarm the system and to reset any 
alarm that occurred when you powered up the 
system.  
The AWAY indicator is extinguished to signify 
that the system is disarmed. 
If any zone indicator is flashing, an alarm 
occurred in that zone.   
If a zone indicator is lit constantly, the zone is 
unsealed. 
Connect the backup battery. 
Enter the default Installer Code (1234) and press 
[AWAY].   
Two beeps sound and the
 STAY and AWAY 
indicators flash simultaneously to indicate that 
you entered Installer’s Programming Mode. 
When entering Installer’s Programming Mode, 
you are automatically positioned at Location 000, 
the first digit of the Primary Telephone Number 
for Receiver 1. 
Enter the Primary Telephone Number, the 
Secondary Telephone Number, and the 
Subscriber ID Number for Receiver 1.   
Refer to Sections 11.111.2, and 11.5 for more 
information about programming these numbers. 
When programming the telephone numbers for 
Receiver 1 and Receiver 2, you must program a 
0 as a 10. Programming a 0 in the telephone 
number indicates the end of the dialing 
sequence. Unless otherwise stated, program a 0 
as a 0 in all locations other than the telephone 
numbers for Receiver 1 and Receiver 2, and the 
Call Back Telephone Number. 
If required, set the Test Report time.  
Program any other required changes. Otherwise, 
factory default settings are used. Refer to Section 
15.28 Test Reporting Time
 for more information. 
Enter command [9 6 0] and press [AWAY] to exit 
from Installer’s Programming Mode.   
Two beeps sound and the STAY and AWAY 
indicators are extinguished. The system is 
returned to the disarmed state and is ready for 
use. Refer to Section 7.4 Installer’s Programming 
Commands
 for more information. 
Use the Master Code to set the date and time.   
Refer to Section 1.2.1 Set the Date and Time for 
more information. 
1.2.1 
Set the Date and Time 
1.  Enter your Master Code and press [6][AWAY]. 
Three beeps sound and the STAY and AWAY 
indicators flash. 
2.  Enter the day, month, year, hour, and minute in 
DD, MM, YY, HH, MM format (where DD is 
the day of the month, MM is the month of the 
year, YY is the year, HH is the hour of the day, 
and MM minute of the day) and press [AWAY]. 
Use 24:00 hour format when programming the 
hour of the day. 
Two beeps sound and the STAY and AWAY 
indicators are extinguished. If a long beep 
sounds, there was an error when you entered the 
date and time. 
Example 
To set the date and time for the 1st January 2004 at 
10:30 PM, enter: 
[2 5 8 0 6][AWAY][0 1 0 1 0 4 2 2 3 0][AWAY] 
1.2.2 
ICP-CC488 Zone Defaults 
The default zone settings for the control panel are 
listed in Table 1 on page 9. You can program Zones 1 
to 8 to any of the zone types. Refer to Table 2 on 
page 10 for the zone types you can select. 
Table 1: 
Zone Defaults for the ICP-CC488  
 
Zone 
Zone Type 
Zone 
Zone Type 
1 Delay-1  5  Instant 
2 Handover 6  Instant 
3 Handover 7  Instant 
4 Handover 8  24-Hour 
Tamper