Bosch ICP-CC488 User Manual

Page of 118
ICP-CC488 | Installation Guide | 22.0  
Terminals and Descriptions 
EN | 95 
 
 
Bosch Security Systems, Inc. | 12/08 | F01U089457-02 
 
22.3 Diagrams 
Figure 23:  ICP-CC488 Wiring Diagram 
 
1 –  605 plug 
2 –  6 (Red) Telecom line (street) 
5 (Yellow) Internal phone line 
3 and 4 Not used  
2 (Black) Telecom line (street) 
1 (Green) Internal phone line 
3 –  Zone 1 
4 –  Zone 5 
5 –  Zone 2 
6 –  Zone 6 
7 –   Power to external equipment:  
12 V @ 400 mA  
8 –   PIR  
9 –   Zone 8 
10 – Zone 4 
11 – Zone 7 
12 – Zone 3 
13 – Piezo siren 
14 – Smoke detector 
15 – Strobe 
16 – Horn speaker  
17 – Codepad 
18 – Yellow  
19 – Green 
20 – Red 
21 – Black 
22 – Battery 
23 – 18 VAC 1.3 A plug pack 
(TF008) 
24 – Link between +12 V and Comm