ICP-CC404 | Installation Guide | 6.0   System Functions 
 
 
Bosch Security Systems, Inc. | 12/08 | F01U089401-02 
27
 
If horn speaker indication beeps are enabled, one 
beep sounds from the horn speaker. If strobe 
indications are enabled, the strobe flashes for 3 sec to 
indicate the system is disarmed. 
5.5.5 Panic 
Alarm 
Press and hold both [AWAY] and [STAY] together 
for 2 sec.   
An audible Panic Alarm is initiated that activates the 
horn speaker, strobe, and internal sirens. 
 
 
If Option 1 is selected in Location 425 
(refer to Section 18.2 System Options 2 
on page 73), the remote radio Panic 
Alarm is also silent. 
 
5.5.6 Remote 
Outputs 
The [DOOR] and [AUX] buttons on the four-channel 
hand-held transmitter can operate two remote 
outputs. Only the installer can program these outputs. 
You can use the Output Event Types listed in 
Table 18. Refer Section 16.0 Programmable Outputs for 
more information. 
 
Table 18: 
Remote Output Event Types 
 
Output 
Event Type 
Description 
Page 
2,11 
Radio Control Output 1 
67 
2,12 
Radio Control Output 2 
67 
2,13 
Radio Control Output 1 – not 
armed in AWAY Mode 
68 
2,14 
Radio Control Output 2 – not 
armed in AWAY Mode 
68 
 
To turn Output 1 on: 
Press and hold [DOOR] for 2 sec. 
Output 1 turns on. 
To turn Output 1 off: 
Press and hold [DOOR] for 2 sec. 
Output 1 turns off. 
To turn Output 2 on: 
Press and hold [AUX] for 2 sec. 
Output 2 turns on. 
To turn Output 2 off: 
Press and hold [AUX] for 2 sec. 
Output 2 turns off. 
 
 
All reset times for the [DOOR] and 
[AUX] buttons are referenced to 
Polarities 1 and 8. Reset times vary 
depending on the polarity used. 
 
6.0   System Functions 
This section explains more advanced features, such as 
Installer Code, Master Code, and hold-down 
functions used for testing and regular maintenance of 
the system.  
6.1 
Installer Code Functions 
Installer Code functions allow the installer to perform 
various system tests and tasks without knowing a 
Master Code. 
To access the required Installer Code function, enter 
the Installer Code and corresponding function digit, 
and press [AWAY]. The Installer Code functions are 
listed in Table 19
You can only access these functions when the system 
is disarmed. 
 
Table 19: 
Installer Code Functions 
 
Function Description 
Reserved 
Set the number of days until the first Test 
Report 
(Section 6.1.1
Change domestic telephone numbers 
(Section 6.1.2
Change the Telco arming or disarming 
sequence 
(Section 6.1.3 on page 28) 
Setting STAY Mode 2 zones 
(Section 6.1.4 on page 30) 
Satellite Siren (EDMSAT) Service Mode 
(Section 6.1.5 on page 30) 
Turn Telephone Monitor Mode on and off 
(Section 6.1.6 on page 31) 
7 Walk 
Test 
Mode 
(Section 6.1.7 on page 31) 
Event Memory Recall Mode 
(Section 6.1.8 on page 31) 
9 Reserved 
 
6.1.1 
Set the Number of Days until the First Test 
Report 
This function determines when the system sends the 
first Test Report (Contact ID Event Code 602). If you 
do not use this Installer Code Function, the first Test 
Report is sent to the base station receiver after the 
repeat interval programmed in Location 366 (refer to 
Section 15.21 Test Reporting Time on page 63). If you 
want the system to send the first Test Report sooner 
than the repeat interval, use this function to set when 
the first Test Report is sent.