Bosch ICP-CC404 User Manual

Page of 98
ICP-CC404 | Installation Guide | 10.0   Dialer Reporting Formats 
 
 
42 Bosch 
Security 
Systems, 
Inc. | 12/08 | F01U089401-02
 
10.0  Dialer Reporting Formats 
10.1 Transmission 
Formats 
The ICP-CC404 Control Panel provides a number of 
transmission formats for its dialing and 
communication features. Program the transmission 
format for Receiver 1 in Location 033 and the 
transmission format for Receiver 2 in Location 073 
(refer to Section 11.4 Transmission Format for Receiver 1 
and Receiver 2
 on page 47). The control panel is set at 
the factory to report in the Contact ID Format. 
10.1.1  Contact ID Format 
Contact ID Format can identify hundreds of 
protection zones by their unique codes. This format 
provides a single-digit Event Qualifier and a three-
digit Event Code that quickly identifies the reported 
condition. 
In general, Contact ID Format is very simple because 
most of the Event Codes and Point ID Codes are 
predefined. The base station software usually can 
identify an alarmed zone by its Point ID Code and 
usually pays little attention to the Event Code. 
Refer to Table 33 on page 43 for more information 
about the ICP-CC404 Point ID Codes. 
 
Table 32: 
Contact ID Format Breakdown 
 
Subscriber ID 
Number 
 
Qualifier 
 
Event Code 
 
Group Number 
 
Point ID Number 
SSSS 
XYZ 
GG 
CCC 
Four-digit 
Subscriber ID 
Number 
Event Qualifier, which provides 
specific event information: 
1 – New event or opening 
3 – New restore or closing  
Event Code 
(comprised of three 
hex digits) 
Group Number 
(comprised of two 
hex digits) 
Point ID Number 
(comprised of three 
hex digits)