ICP-CC404 | Installation Guide | 10.0   Dialer Reporting Formats 
 
 
Bosch Security Systems, Inc. | 12/08 | F01U089401-02 
45
 
Figure 6:  Basic Pager Display 
 
1 –  Subscriber ID number 
2 –  Zone status 
3 –  System status 
4 –  0 – Zone Normal 
1– Alarm 
2 – Manually Isolated 
5 –  8 – Disarmed 
9 – Armed 
6 –  0 – Normal 
1 – Panic/Duress 
2 – Fire Alarm 
3 – Medical Alarm 
7 –  0 – AC Normal 
1 – AC Failure 
8 –  0 – System Normal 
1 – System Fault 
10.2  Basic Pager Display Information 
Subscriber ID Number 
This is the identification number of the control panel 
and is programmed in Locations 034 to 039 for 
Receiver 1 and Locations 074 to 079 for Receiver 2 
(refer to Section 11.5 Subscriber ID Number for Receiver 1 
and Receiver 2
 on page 47). The pocket pager displays 
only the last three digits of the Subscriber ID 
Number. 
Zone Status 
The zone status display shows you the status of each 
zone (1 to 8) of the control panel. Table 37 describes 
each status number when displayed on a pocket 
pager. 
 
Table 37: 
Zone Status Display Descriptions 
 
Status Zone 
Description 
Zone normal 
The zone is sealed. 
1 Alarm 
The zone is unsealed and in alarm. 
Zone bypassed 
A system operator manually isolated the 
zone. Refer to Section 4.11 Isolating Zones 
on page 21 for information about manually 
isolate a zone(s) prior to arming the system  
Refer to Section 15.1 Zone Status – 
Bypass Reports
 on page 60 for more 
information. 
3 Zone 
trouble 
 
A zone was left unsealed after the end of 
Exit Time. Refer to Section 15.2 Zone 
Status – Trouble Reports
 on page 60 for 
more information.