ICP-CC404 | Installation Guide | 13.0   Access Code 
 
 
Bosch Security Systems, Inc. | 12/08 | F01U089401-02 
51
 
Open/Close Reports must be enabled in Locations 
333 and 334 (refer to Section 15.6 Open/Close Reports on 
page 61) for this option to work.  
4 – Delay Siren until Transmission Complete 
If this option is selected, the EDMSAT, horn speaker, 
bell, and strobe outputs are not activated until after 
the control panel sends the message and the base 
station receiver sends a kiss-off back to the control 
panel. If multiple messages are sent, the sirens are 
activated after the last kiss-off is sent. 
If a Codepad Panic, Codepad Fire, or Codepad 
Medical Alarm is activated, the EDMSAT, horn 
speaker, bell, and strobe outputs operate immediately. 
8 – Extend Time to Wait for Handshake from 30 to 
60 Sec 
By default, the control panel waits approximately 30 
sec for receipt of a valid handshake tone after it dials 
the monitoring station. The handshake tone indicates 
to the control panel that it reached the monitoring 
station and can now send its messages. Selecting this 
option extends this wait time from 30 sec to 60 sec. 
12.3  Dialer Options 3 
Program the selected Dialer Options 3 in 
Location 179.  
The default is 0. The options are: 
1 – Set DTMF Dialing Pulses to 1 Digit/Sec 
If this option is not selected, the Australian DTMF 
dialing format dials at 5 digits per sec (that is, 100 ms 
tone, 100 ms pause, 100 ms tone, 100 ms pause). 
If this option is selected, the Australian DTMF dialing 
format dials at the rate of 1 digit per sec (that is, 500 
ms tone, 500 ms pause). 
2 – Reserved 
4 – Change Decadic Dialing to 60/40 
Some countries have different requirements for 
decadic dialing. Selecting this option changes the 
dialing characteristics from 65/35 (Australian 
Standard) to 60/40. Select this option only when the 
control panel is used in a country that requires 
decadic dialing as 60/40. This option has no effect 
when using DTMF tone dialing. 
8 – Reserved 
12.4 Alarm 
Link 
Options 
For more information about this location, refer to 
Section 8.2 Alarm Link Options on page 40.  
13.0  Access Code 
This section describes the access codes that assign 
privileges and access functions for User Code holders 
of the system. There are two types of access codes, 
the Installer Code and User Codes. Each code allows 
access and operation of control panel functions. 
13.1 Installer 
Code 
Program the Installer Code in 
Locations 181 to 184.  
The default Installer Code is 
1 2 3 4. 
Use this code to access Installer’s Programming 
Mode. The Installer Code can be up to four digits 
long. After power is applied to the control panel, the 
Installer Code can disarm the system if it is the first 
code used. The next time the Installer Code is used 
enables access to Installer’s Programming Mode. 
Installer Code functions allow the installer to execute 
functions when the system is disarmed without the 
customer’s Master Code. Refer to Section 6.1 Installer 
Code Functions
 on page 27 for more information. 
Refer to Section 2.1 Programming with the Remote 
Codepad
 on page 9 for more information on 
programming the system. 
13.2 User 
Codes 
The purpose of User Codes is to arm and disarm the 
system and to perform other specific functions. A  
Master Code holder can change or delete User Codes.  
Program User Codes 1 to 8 in 
Locations 185 to 224.  
Program Remote Radio User Codes 9 to 16 in 
Locations 225 to 264. 
The default User Codes are listed in Table 40
 
Table 40: 
Default User Codes 
 
User Number 
Locations 
Code 
Priority 
User #01 
185 to 189 
2     5     8    0 
10 
User #02 
190 to 194 
15  15  15  15 
User #03 
195 to 199 
15  15  15  15 
User #04 
200 to 204 
15  15  15  15 
User #05 
205 to 209 
15  15  15  15 
User #06 
210 to 214 
15  15  15  15 
User #07 
215 to 219 
15  15  15  15 
User #08 
220 to 224 
0    15  15  15 
RF User #09 
225 to 229 
15  15  15  15 
RF User #10 
230 to 234 
15  15  15  15 
RF User #11 
235 to 239 
15  15  15  15 
RF User #12 
240 to 244 
15  15  15  15 
RF User #13 
245 to 249 
15  15  15  15 
RF User #14 
250 to 254 
15  15  15  15 
RF User #15 
255 to 259 
15  15  15  15 
RF User #16 
260 to 264 
15  15  15  15