ICP-CC404 | Installation Guide | 14.0   Zone Information 
 
 
54 Bosch 
Security 
Systems, 
Inc. | 12/08 | F01U089401-02
 
If you select split EOL resistors, the control panel 
looks for four Burglary Zones (1 to 4) with 3.3 kΩ 
EOL resistors and four 24-Hour Zones (5 to 8) 
consisting of 6.8 kΩ resistors connected in parallel. 
The Zone 1 terminal on the PCB is the terminal for 
Zones 1 and 5. 
 
 
Use caution when using split EOL 
resistors to create four Burglary Zones 
and four 24-Hour Zones. This 
configuration is only suitable for normally-
closed (NC) contacts. If normally-open 
(NO) contacts are used, as is the case 
with most smoke detectors, a short circuit 
on one zone activates both zones 
connected in parallel. 
If you require NO contacts when using 
split EOL resistors, refer to Figure 8 for 
information on how to connect NO 
contacts. 
 
Figure 7:   Split EOL Resistors Using 
NC Contacts 
10 
10 
10
10
 
1 – Zone 1 
2 – Zone 2 
3 – Zone 3 
4 – Zone 4 
5 – Zone 5 
6 –  Zone 6 
7 –  Zone 7  
8 –  Zone 8 
9 –  3.3 k
Ω
 
10 – 6.8 k
Ω
 
 
Figure 8:   Split EOL Resistors Using 
NO Contacts 
 
 
 
 
14.3 Zone 
Programming 
The programming information for each zone is stored 
in seven locations divided into three groups. The first 
three locations determine how the zone operates, the 
next two locations set up a number of zone options, 
and the last two locations store the dialer reporting 
information for the zone. 
Zone Operating Information 
These locations store the Zone Type (for example, 
Delay-1, Instant, or 24-Hour), the Zone Pulse Count, 
and the Zone Pulse Count Time. The Zone Pulse 
Count specifies the number of times the zone must 
activate within the time specified in the Zone Pulse 
Count Time. Refer to Sections 14.3.1 Zone Types14.3.2 
Zone Pulse Count
 on page 56, and 14.3.3 Zone Pulse 
Count Time
 on page 56 for more information. 
Zone Options 
These two locations allow you to select from a 
number of options. Refer to Sections 14.3.4 Zone 
Options 1
 on page 57 and 14.3.6 Zone Options 2 on 
page 58 for more information. 
Zone Reporting Information 
This information includes the locations for the Zone 
Report Code and the Zone Dialer Options.