ICP-CC404 | Installation Guide | 14.0   Zone Information 
 
 
Bosch Security Systems, Inc. | 12/08 | F01U089401-02 
59
 
If you do not want the system to send Zone Bypass 
Reports, program Locations 325 and 326 to 0 (refer to 
Section 15.1 Zone Status – Bypass Reports on page 60). 
4 – Forced Arming Allowed 
If this option is selected, the system can be armed 
with the zone unsealed. If this option is not selected, 
the system does not allow the User Code holder to 
arm the system until the zone is sealed or manually 
isolated. Refer to Section 4.11 Isolating Zones on 
page 21 for more information. 
8 – Zone Restore Report 
If this option is selected, the zone sends Restore 
Reports when the zone is restored. If this option is 
not selected, the zone does not send Restore Reports 
when the zone is restored. 
If a non-24-Hour zone is not restored when the 
system is disarmed, the system automatically sends a 
Zone Restore Report for that zone. All 24-Hour zones 
send a Zone Restore Report only when the zone is 
restored. 
14.3.7  Zone Report Code 
If you want the control panel to send Zone Alarm 
Reports, program this location as 1. If not, program 
this location as 0. 
14.3.8  Zone Dialer Options 
By default, a zone reports only to Receiver 1. Table 45 
lists the reporting options for the zone. 
 
Table 45: 
Zone Dialer Options 
 
Option Description 
No report required 
1 Receiver 
Receiver 2 
Receiver 1 and Receiver 2 
Receiver 2 only when Receiver 1 fails 
 
14.4  Swinger Shutdown Count for Siren 
Program the Swinger Shutdown Count for Siren in 
Location 323. 
The default value is 
3. 
This location determines the number of times the 
sirens can be activated before lockout options take 
effect. Programming a 0 sets the count to unlimited. 
This location has no effect unless you program at 
least one zone for lockout siren. Refer to Section 14.3.4 
Zone Options 1
 on page 57 to program zones for 
lockout siren.  
Only alarms activated from zone inputs can decrease 
the Swinger Shutdown Counter. Alarms such as 
Codepad Panic, Access Denied, and other system 
alarms do not affect the Swinger Shutdown Count. 
When the sirens are operating, its counter is only 
decreased by the first zone that activated the alarm. 
Any other zones that are activated during Siren Run 
Time do not affect the counter.  
When the Swinger Shutdown Count is reached, all 
zones that were activated are locked out according to 
their individual lockout settings. 
Example 
All eight zones are programmed for lockout siren 
with a Swinger Shutdown Count of 3. If Zone 1 
activates an alarm, the Swinger Shutdown Count is 
decreased by one after the end of Siren Run Time to 
a swinger shutdown count of 2.  
After the Siren Run Time is reset from the previous 
alarm, Zone 2 activates an alarm and activates the 
sirens. After the sirens reset, the swinger shutdown 
count is decreased again to 1.  
If Zone 3 also activates an alarm after the sirens are 
reset from Zone 2, the Swinger Shutdown Count is 
decreased to 0, which locks out all three zones from 
sounding the sirens until the system resets.   
At this point, the Swinger Shutdown Count for Sirens 
resets to 3 and the process of swinger shutdown for 
remaining zones begins again until all zones are 
locked out. 
14.5  Swinger Shutdown Count for Dialer 
Program the Swinger Shutdown Count for Dialer in 
Location 324. 
The default value is 
6. 
This location determines the number of times the 
dialer can be activated before lockout options take 
effect. This location has no effect unless you program 
at least one zone for lockout dialer. Refer to Section 
14.3.4 Zone Options 1
 on page 57 to program zones for 
lockout dialer. 
Only alarms activated from zone inputs can decrease 
the Swinger Shutdown Counter. Alarms such as 
Codepad Panic, Code Retries, and other system 
alarms do not affect the Swinger Shutdown Count. 
When the dialer is online, its counter is only 
decreased by the first zone that activated the alarm. 
Any other zones that are activated while the dialer is 
online do not affect the counter. 
When the Swinger Shutdown Count is reached, all 
zones that were activated are locked out according to 
their individual lockout settings. 
 
If Lockout Dialer is enabled for any zone, 
the last restore signal is not sent until the 
system is disarmed.