ICP-CC404 | Installation Guide | 16.0   Programmable Outputs 
 
 
68 Bosch 
Security 
Systems, 
Inc. | 12/08 | F01U089401-02
 
2,13 
Radio Control Output 1 – Not in AWAY 
Mode 
This output operates when the [DOOR] button on the 
four-channel hand-held transmitter is activated. The 
output does not operate when the system is armed in 
AWAY Mode. 
2,14 
Radio Control Output 2 – Not in AWAY 
Mode 
This output operates when the [AUX] button on the 
four-channel hand-held transmitter is activated. The 
output does not operate when the system is armed in 
AWAY Mode. 
2,15 
Communications Failure after Three 
Unsuccessful Calls 
This output operates after the communication dialer 
makes three unsuccessful calls to the base station 
receiver. The output resets when all messages are sent 
(that is, when the message buffer is empty or when all 
possible attempts are made). 
3,0 Communications 
Failure 
This output operates after the communication dialer 
makes all possible attempts to reach the base station 
receiver. The output resets when the first kiss-off is 
received. This output does not operate for domestic 
formats. 
3,1 Dialer 
Disabled 
This output operates when the Dialer reporting 
functions allowed Option 1 in Location 177 are not 
selected (refer to Section 12.1 Dialer Options 1 on 
page 50). The output resets when Option 1 is 
selected. 
3,2 Dialer 
Active 
This output operates when the communication dialer 
is online. The output resets when the communication 
dialer releases the telephone line. 
3,3 Ring 
Detect 
This output operates when the control panel detects 
an incoming call. The output resets when the ringing 
stops or when the call is answered. 
3,5 
Mimic Zone 1 
3,6 
Mimic Zone 2 
3,7 
Mimic Zone 3 
3,8 
Mimic Zone 4 
3,9 
Mimic Zone 5  
3,10  
Mimic Zone 6 
3,11  
Mimic Zone 7 
3,12 
Mimic Zone 8  
These output types mimic the zone inputs. The 
output operates when the zone is unsealed and resets 
when the zone is sealed. They operate regardless of 
the selected zone type (for example, a zone 
programmed as Not Used can still operate a mimic 
output). This feature operates when the system is 
armed or disarmed. 
4,5 Global 
Chime 
This output operates when any Chime zones are 
activated. The output resets when the zone is 
resealed. Refer to Section 14.3.1 Zone Types on page 55 
for more information. 
4,6 Zone 
Not 
Sealed 
This output operates when a Burglary Zone is 
unsealed. Chime zones do not operate this output. 
4,7 
Zone Not Sealed after Exit Time 
This output operates at the end of Exit Time if a 
Burglary Zone is unsealed. The output resets when all 
zones are sealed or the system is disarmed. Chime 
zones do not operate this output. 
4,9 
AC Mains 60 Hz or 50 Hz 
This output is activated when the AC mains supply 
frequency is 60 Hz. The output resets if the AC mains 
supply returns to 50 Hz. 
16.3 Output 
Polarity 
There are fifteen different polarities. Each polarity is 
designated by a number that you program into the 
third location for the output.