ICP-CC404 | Installation Guide | 19.0   Optional Equipment 
 
 
Bosch Security Systems, Inc. | 12/08 | F01U089401-02 
77
 
19.7  CP5 Eight Zone LCD Codepad 
(CP508LW) 
This codepad operates with the range of control 
panels. This codepad has a fixed icon display and 
provides indications for up to eight zones. 
19.8  CP105A Night Arm Station 
The night arm station has a panic button and allows 
the user to arm and disarm the system in STAY 
Mode 1 from a bedroom or sitting room. Enable the 
night arm station to operate with the system by 
selecting Option 8 in Location 427 (refer to Section 
18.4 System Options 4
 on page 74). 
19.9  PS101 Power Supply Module 
The PS101 Power Supply Module provides 13.8 VDC 
at currents up to 1 A. Use the module with the TF008 
18 VAC plug pack. 
The module provides standard, fully short-circuit 
proof, power out, and battery charging terminals, and 
a DC LED indicator. If the application requires an 
uninterruptible power supply, a rechargeable sealed 
lead-acid battery can be installed. If there is a mains 
failure, the power supply switches to battery power 
without interrupting the supply to the load. 
19.10  TF008 Plug Pack (TF008) 
The TF008 plug pack is used with control panels. The 
plug pack includes built-in thermal fuses that blow 
during overload or fault conditions to eliminate a 
possible fire threat due to excessive heat buildup 
inside the casing. 
The plug pack incorporates a three-wire flying lead 
that enables a mains earth connection between the 
equipment and the plug pack. This connection might 
be required for lightning protection on equipment 
connected to phone lines or for safety reasons such as 
earthing of metal enclosures.