Bosch ICP-CC404 User Manual

Page of 98
ICP-CC404 | Installation Guide | 20.0   Terminals and Descriptions 
 
 
Bosch Security Systems, Inc. | 12/08 | F01U089401-02 
83
 
Figure 13:  Telecom Connection Diagram for Australia 
   
 
   
 
   
 
   
1
   
 
   
2
   
 
   
3
   
 
   
9
 
7
  
 
  
4
   
 
   
5
  
6
   
 
   
10
 
2
  
3
  
9
  
7
   
 
   
8
 
1 –  Control panel 
2 –  Red wire 
3 –  Yellow wire 
4 –  6P4C plug (top view) 
5 –  605 plug 
6 –  Internal phones 
7 –  Green wire 
8 –  Telecom line 
9 –  Black wire 
10 –  611 socket 
1 (green): internal phone line 
2 (black): telecom line (street) 
3 and 4: not connected 
5 (yellow): internal phone line 
6 (red): telecom line (street) 
 
Figure 14:  Telecom Connection Diagram for New Zealand 
 
 
 
 
 
 
 
1
 
 
 
3
 
 
 
2
 
 
 
5
 
 
 
6
 
 
 
8
 
 
 
9
 
 
 
 
1 –  Control panel 
2 –  Black wire  
3 –  Red wire  
4 –  RJ45 plug (top view) 
5 –  Internal phones  
6 –  Telecom line 
7 –  (black): telecom line (street) 
(green): internal phone line  
(red): telecom line (street)  
(yellow): internal phone line 
8 –  Green wire 
9 –  Yellow wire  
 
Figure 15:  Telecom Connection Diagram for China 
  
5
8
10 
 
1 –  Control panel 
2 –  Red wire  
3 –  Black wire  
4 –  4P4C plug (top view) 
5 –  RJ12 plug (top view) 
6 –  Telecom line 
7 –  Internal phones 
8 –  Rear view of telephone plate 
(green): internal phone line  
(black): telecom line (street) 
(yellow): internal phone line 
(red): telecom line (street)  
9 –  Yellow wire 
10 –  Green wire