Bosch FW5.50 User Manual

Page of 94
Camera Browser Interface
Encoder Settings | en
47
Bosch Security Systems
Software manual
AM18-Q0611 | v5.50 | 2012.03
To obtain the highest quality at the lowest bandwidth, even in 
the case of increased movement in the picture, configure the 
quality settings as follows:
1.
Observe the coverage area during normal movement in the 
preview images.
2.
Set the value for Min. P-frame QP to the highest value at 
which the image quality still meets your needs.
3.
Set the value for I/P-frame delta QP to the lowest possible 
value. This is how to save bandwidth and memory in 
normal scenes. The image quality is retained even in the 
case of increased movement since the bandwidth is then 
filled up to the value that is entered under Maximum bit 
rate.
9.1.9
Default
Click Default to return the profile to the factory default values.