Bosch FW5.50 User Manual

Page of 94
Camera Browser Interface
Alarm | en
65
Bosch Security Systems
Software manual
AM18-Q0611 | v5.50 | 2012.03
11.3
Audio Alarm
Alarms can be generated based on audio signals. Configure 
signal strengths and frequency ranges so that false alarms, for 
example, machine noise or background noise, are avoided.
Set up normal audio transmission before configuring the audio 
alarm.
11.3.1
Audio alarm
Select On for the device to generate audio alarms.
11.3.2
Name
The name makes it easier to identify the alarm in extensive 
video monitoring systems, for example with the Bosch Video 
Client and the Bosch Video Management System. Enter a 
unique and clear name here.
11.3.3
Signal Ranges
Exclude particular signal ranges in order to avoid false alarms. 
For this reason the total signal is divided into 13 tonal ranges 
(mel scale). Check or uncheck the boxes below the graphic to 
include or exclude individual ranges.
11.3.4
Threshold
Set up the threshold on the basis of the signal visible in the 
graphic Set the threshold using the slide control or, 
alternatively, move the white line directly in the graphic using 
the mouse.
11.3.5
Sensitivity
Use this setting to adapt the sensitivity to the sound 
environment and effectively suppress individual signal peaks. A 