Bosch LP880 User Manual

Page of 32
CC880/LP880, SC8016 | Operators Guide | 28.0 
PET Pager Reporting 
EN | 19 
 
 
Bosch Security Systems | 6/04 | 920036O.OG.162 
 
28.0 PET Pager Reporting 
The system can be configured by your security 
company to report to a pocket pager when an 
alarm and/or any system event occurs. When 
using either of these two reporting formats, easy to 
understand text messages are received so that the 
appropriate action can be taken. 
Table 17 lists all the events that can be reported in 
PET pager formats. 
Table 17:  PET Pager Messages 
 
Event At Control Panel 
PET Message 
AC Fail 
AC Fail 
AC Restore 
AC Restore 
Area Has Been Armed 
Close Area #, User # 
Area Has Been Disarmed 
Open Area #, User # 
Burglary Zone Has Triggered 
Alarm Zone # 
Burglary Zone Has Restored 
Restore Zone # 
Burglary Zone Triggered, Area # 
Alarm Zone #, Area # 
Burglary Zone Restored, Area # 
Restore Zone #, Area # 
Access Denied – Codepad Tamper 
Codepad Tamper 
Data Programming Change 
Data Change 
System Is Armed 
Close User # 
System Is Disarmed 
Open User # 
Codepad Duress 
Duress, Open User # 
Low Battery 
Low Battery 
Low Battery Restore 
Battery Restore 
Codepad Panic Alarm 
Panic 
Codepad Fire Alarm (V1.37+) 
Fire 
Codepad Medical Alarm (V1.37+) 
Medical 
Test Report 
Test 
Zone Automatically Isolated When 
Armed 
Bypass Zone # 
Disarming When Zone Has Been 
Isolated 
Bypass Restore Zone # 
Zone Unsealed At End Of Exit Time 
Trouble Zone # 
Zone Has Restored After Exit Time 
Trouble Restore # 
24 Hour Zone Triggered 
24 Hour Alarm # 
24 Hour Zone Restored 
24 Hour Restore # 
24 Hour Fire Zone Triggered 
Fire Zone # 
24 Hour Fire Zone Restored 
Fire Restore # 
The # symbol represents the zone or area number 
in the transmission. 
The following example shows how a single 
transmission is received on the PET pager. A 
similar message to the one below is seen when the 
control panel is armed by User 1. 
Table 18:  Example of a Single Transmission 
 
1111 
CLOSE USER 
01 
Subscriber ID Number 
System Armed 
User #1 
The Subscriber ID number is a unique 4 digit 
number identifying which alarm system made the 
call. Only your security company can program the 
Subscriber ID number (Factory Default = 0000).