1.0 Introduction 
Congratulations on selecting the Solution-16 Control 
Panel to protect you and your property. Take time to 
read through this manual and familiarise yourself 
with the operating features of this system. In all 
aspects of planning, engineering, styling, operation, 
convenience, and adaptability, we have sought to 
anticipate your every possible requirement. 
Programming simplicity and speed were some of the 
major considerations and we believe that our 
objectives in this area were more than satisfied. 
This manual explains all aspects of operating the 
control panel. All system parameters and options are 
detailed; however, suitability is left up to the 
individual. Every system can be tailored to meet all 
requirements quickly and easily. 
2.0 Specifications 
Table 1: 
Specifications 
 
Temperature 
Range 
0
o
C to +45
 o
C  
(+32
 o
F to +113
 o
F) 
Humidity 
10% to 95% 
Power Source 
TF008 Plug Pack –  
240 V/18 V AC @ 1.3 A 
Stand-By Current 
65 mA 
Current Draw In 
Alarm Condition 
115 mA 
Current Draw In 
Alarm Condition 
With Codepad 
105 mA 
Back-Up Battery 
7 Ah/12 V DC rechargeable 
sealed lead acid battery 
Dimensions (case, 
packed in carton) 
306 mm x 262 mm x 84 mm  
(12.05 in. x 10.31 in. x 3.31 in.)
Weight 
2.5 kg 
(5.51 lbs.) 
Supplier Code 
N771 
New Zealand 
Telepermit 
PTC 211/95/263 
Malaysia Approval 
Number 
Pending 
 
 
 
The Austel permit issued for this product is 
subject to the following conditions: 
The Solution-16 Control Panel 
(CC880/LP880, SC8016) may only be 
powered by a Bosch Security Systems 
TF008 plug pack (Approval Number 
Q92128). 
 
 
Test the sirens, strobe, and zones at 
weekly intervals. See Section 18.0 Testing 
for further information. 
3.0 Codepad 
Indicators 
Figure 1:  CP5 Eight Zone LED Codepad 
 
 
 
Figure 2:  Sixteen Zone LED Codepad