Bosch D7412G User Manual

Page of 142
D9412G/D7412G | Program Entry Guide | 5.0 RADXSKED
EN | 100
Bosch Security Systems | 1/04 | 47775E
W# Xept Holiday
Default:
No
Selection:
Yes or No
Yes
Do not activate this window on
holidays.
To use this selection, the window must
be programmed to activate on at least
one day of the week and a Holiday
Index must be enabled.
No
A holiday does not prevent this
window from activating.
You also use this selection if Opening
and/or Closing Windows are only
needed on certain days of the year. Do
not program the windows to execute
on any days of the week. Instead,
program 
Xept Holiday
 No, and select
at least one Holiday Index with the
days of the year you want the window
to be active.
Determine if the window is disabled on holidays, or
is active only on holidays.
To prevent the windows from activating on certain
days of the year, program 
Xept Holiday
 Yes, and
enable at least one Holiday Index. When 
Xept
Holiday
 is programmed Yes, the window executes
on the days of the week programmed unless the date
is designated as a Holiday by the Holiday Index(es)
selected.
Holiday Indexes for O/C Windows
You can enable up to four Holiday Indexes for use
with Opening/Closing Windows. Enable at least one
Holiday Index if
 W# Xept Holiday
 is programmed
Yes for this window, or if you want this window to
activate only on specific dates. Holidays are
programmed in Section 5.3 Holiday Indexes.
W# Holiday 1
Default:
No
Selection:
Yes or No
Yes
Use Holiday Index 1 with this window.
No
Do not use Holiday Index 1 with this
window.
W# Holiday 2
Default:
No
Selection:
Yes or No
W# Holiday 3
Default:
No
Selection:
Yes or No
W# Holiday 4
Default:
No
Selection:
Yes or No
W# Area 1 [through 8]
Default:
No
Selection:
Yes or No
Yes
Activate the window in the area
number (#) specified.
No
Disable the window in the area
number (#) specified.
Eight separate program items determine whether a
particular window activates in each of the eight areas
of the control panel.