Bosch D7412G User Manual

Page of 142
D9412G/D7412G | Program Entry Guide | 2.0 9000MAIN
EN | 31
Bosch Security Systems | 1/04 | 47775E
P## Auto Functions Event
Default:
See 
Program Record Sheet
Selection:
Yes or No
P## RAM Event
Default:
See 
Program Record Sheet
Selection:
Yes or No
P## Relay Event
Default:
See 
Program Record Sheet
Selection:
Yes or No
P## Point Event
Default:
See 
Program Record Sheet
Selection:
Yes or No
P## Usr Chng Evt
Default:
See 
Program Record Sheet
Selection:
Yes or No
2.7
RAM Parameters
Use these program items to enable Remote Account
Manager (RAM) functions in the control panel using
the on-board phone connection. Two other methods
of remote programming are available (external
modem or LAN/WAN connection) using RAM. See
Section 6.4 SDI RAM Parameters for further
information on these types of remote programming.
2.7.1
Uploading and Downloading Reports
If the control panel is programmed to send reports
in modem format, when RAM makes contact with
the control panel and the passcode is incorrect, the
control panel sends a RAM Access Fail Report to
the D6500/D6600. RAM Access Fail is also
generated when the call is not terminated with either
a Good-bye or Reset-bye command.
RAM ACCESS OK is sent according to phone
routing when a Good-bye command is entered from
RAM to terminate the call.
When a Reset-bye is used to terminate the call, a
Remote Reset Report is sent to the D6500/D6600,
and a RAM ACCESS OK is placed into the control
panel’s event log. Reports in the event log that were
not sent prior to the Reset-bye are never sent to the
D6500/D6600.
When RAM programming changes parameters, a
Parameters Changed Report is sent to the
D6500/D6600. If any programming changes are
made, perform a Reset-bye.
When RAM attempts to make contact with the
control panel, the RAM passcode and DataLock
code are verified. If the control panel passcode
matches and the DataLock code does not, the
control panel still generates a RAM Access OK
Event. However, the session ends immediately.
To disable remote programming, enter Blank in
both 
Answer Armed
 and 
Answer Disarmed
prompts in this section.
2.7.2
Log Threshold Reports
If communication with RAM is not successful, or if
no phone number is programmed in 
RAM Ph
, the
control panel generates Log Threshold and Bad Call
to Ram. This indicates the log is filling and the
control panel cannot download its events.
If there is no 
RAM Ph
 programmed, the control
panel generates the Log Threshold and Bad Call to
RAM Events immediately. Bad Call to RAM Events
are currently logged locally only. If there is a 
RAM
Ph
 programmed, the control panel makes multiple
attempts to reach RAM before sending the reports.
See the 
RAM Ph
 prompt in the following section for
an explanation of dialing characteristics.
2.7.3
RAM Callback Reports
When dialing the RAM phone number, the control
panel immediately makes two attempts to reach
RAM. If the control panel does not reach RAM on
the first two attempts, it waits 10 minutes then tries
six more times with a 10-minute interval between
each attempt. One hour after the last failed attempt,
the control panel again starts dialing the RAM
phone number. It immediately makes two more
attempts then waits 10 minutes and tries six more
times with 10-minute intervals between each attempt
before generating a Bad Call to RAM Report and
abandoning the effort.
Remote Program Dialing Exception: When a
RAM phone number is programmed, the user can
call RAM by entering [COMMAND][4][3] and
pressing the [NEXT] key until 
CALLRAM?
 is
displayed. Press [ENTER]. When performing this
function, only one attempt is made to contact RAM.