Bosch D7412G User Manual
D9412G/D7412G | Program Entry Guide | 2.0 9000MAIN
EN | 63
Bosch Security Systems | 1/04 | 47775E
L## Chg Display
Default:
See
Program Record Sheet
Selection:
Blank or E
#15 Change Display [COMMAND][4][9]
Change the display (bright display, dim display, and
time display) in the area where this command center
is assigned.
time display) in the area where this command center
is assigned.
L## Chg Time/Date
Default:
See
Program Record Sheet
Selection:
Blank or E
#16 Change Time and Date [COMMAND][4][5]
Change the date and time for the control panel in
this area.
this area.
L## Chg Passcode
Default:
See
Program Record Sheet
Selection:
Blank or E
#17 Change Passcodes [COMMAND][5][5]
Change a user passcode.
L## Add User
Default:
See
Program Record Sheet
Selection:
Blank or E
#18 Add User [COMMAND][5][6]
Add/change users, add/change authority levels,
add/change tokens/cards.
add/change tokens/cards.
9210 NOT READY
appears if a door
controller is not assigned (see CC#
Assign Door in Section 2.10.1 Cmd Cntr
(Command Center) Assignment) to the
command center used to add/change
tokens/cards.
Assign Door in Section 2.10.1 Cmd Cntr
(Command Center) Assignment) to the
command center used to add/change
tokens/cards.
L## Del User
Default:
See
Program Record Sheet
Selection:
Blank or E
#19 Delete User [COMMAND][5][3]
Delete users.
0101
0101
0101
0101
0101
Although an individual user (001 through
249) can be deleted separately, take
caution. User passcode, token/cards
cannot be deleted individually within a
group (for example, User 001 has three
additional sub-users that use the same
authority levels for that group). When
dealing with an individual user, change
that user’s token/passcode so other
users in the group do not need to be re-
added.
249) can be deleted separately, take
caution. User passcode, token/cards
cannot be deleted individually within a
group (for example, User 001 has three
additional sub-users that use the same
authority levels for that group). When
dealing with an individual user, change
that user’s token/passcode so other
users in the group do not need to be re-
added.
L## Extend Close
Default:
See
Program Record Sheet
Selection:
Blank or E
#20 Extend Close [COMMAND][5][1]
Change the closing time in the area where the
function is entered.
function is entered.
L## View Log
Default:
See
Program Record Sheet
Selection:
Blank or E
#21 View Log (MENU FUNCTION only)
View all panel-wide events in the control panel’s
memory log.
memory log.
L## Print Log
Default:
See
Program Record Sheet
Selection:
Blank or E
#22 Print Event Log (MENU FUNCTION only)
Print all panel-wide events from the log to the
printer in the area where the user is executing this
function.
printer in the area where the user is executing this
function.
This item can also be accessed using the
Service Menu ([9][9][ENT]).
Service Menu ([9][9][ENT]).
L## User Cmd 7
Default:
See
Program Record Sheet
Selection:
Blank or E
#23 User COMMAND 7 [COMMAND][7]
Can be used in Function Menu. Generate the alarm
programmed at COMMAND 7 in the RADXPNTS
Handler.
programmed at COMMAND 7 in the RADXPNTS
Handler.