Bosch 9 6 BLCC110U User Manual

Page of 32
Solution 64
28
Bosch Security Systems   09/06   BLCC110U
User Guide
System > System Testing >
Walk Test All Zones
MENU  7-9-0
This menu allows you to test all zones within an area at the same 
time.  
Enter programming mode (PIN + MENU) then,
1.  Press [MENU] + [7] + [9] + [0].
 
The keypad will display a list of areas that are available to 
walk test zones.
2.  Use the [
] and [] keys to select the area that you want to 
do walk test, then press [OK] to select.  Alternatively, you 
can enter the area number, then press [OK].
 
The keypad will scroll all zones that you can test.
To test Z001
open then close
Zone 1 Name
Press OK or MENU
To test Z002
open then close
Zone 1 Name
Press OK or MENU
3.  Open and close each zone that needs to be tested.  A 
zone that has been successfully tested will no longer 
scroll on the keypad display.
 
When all zones have been tested, the keypad will display:
Selected zones have been
Tested OK
Press OK or MENU
4.  Press [OK] to save and exit, or press [MENU] to exit 
without saving. 
System > System Testing >
Battery Test
MENU  7-9-1
This  menu  allows  you  to  manually  test  the  systems  back  up 
battery.  The Solution 64 will automatically test the battery once 
per day and every time the system is armed.
The battery test can take up to two minutes to complete and the 
keypad will display the voltage of the battery during the test.
Enter programming mode (PIN + MENU) then,
1.  Press [MENU] + [7] + [9] + [2].
 
The keypad will display the battery voltage whilst under 
test:
Battery test in progress.
Please wait..
  
Voltage = 13.4V
To Go Back Press OK
 
If the battery has passed the test, the keypad will display:
Battery test Passed.
Press OK to continue
 
If the battery has failed the test, the keypad will display:
Battery test Failed.
Please Call for Service.
Press OK to continue
2.  Press [OK] to exit.