Alarm Information
15.1 General
The ability to automatically switch video in response to an external signal (usually a 
contact closure) is a necessary feature in any video switching system. The Allegiant 
system permits users with Priority Level 1 to select any 1 of 3 predefined alarm 
response modes (via keyboard User Function 19). A description of these three (3) 
modes appears below. Pictorial examples of the three (3) alarm responses are also 
shown on the following pages.
The system can also be programmed with a wide variety of alarm response charac-
teristics using the optional LTC 8059/00 MCS package or the optional 
LTC 8850/00 GUI Software package.
15.2 Basic Alarm Response Mode
In the Basic alarm response mode, any or all of the monitors can be selected as 
alarm display monitors. Each alarm can then be armed to display its camera(s) on 
any set of armed monitors. Multiple alarms, on the same monitor, will sequence at a 
2 second rate. Note that monitors and alarms can be armed and disarmed individu-
ally as required. Alarmed video automatically clears when the alarm input signal is 
reset.
15.3 Auto Build Alarm Response Mode
This mode uses a set of monitors as alarm display monitors. All system monitors 
may be armed if desired. Each triggered alarm will display its alarm video on a dif-
ferent monitor, starting with the lowest numbered armed monitor. If all the armed 
monitors are already displaying alarm video, subsequent alarms will build on the 
existing alarmed monitors; and each monitor will sequence through its alarm videos 
at a 2 second rate. Note that monitors and alarms can be armed and disarmed indi-
vidually as required. Alarmed video will automatically clear when the alarm input 
signal is reset.
15.4 Sequence and Display Alarm Response Mode 
This mode designates two monitors as alarm response monitors. Monitor #1 is the 
DISPLAY
 monitor (also called a REVIEW monitor) and monitor #2 is the 
SEQUENCE
 (or STEP) monitor. The first alarm appears on both monitors and 
additional alarms begin to sequence at a 2 second rate on the SEQUENCE monitor. 
The DISPLAY monitor holds the first alarmed camera video until manually 
acknowledged through the keyboard. When the first video is cleared from the DIS-
PLAY
 monitor, the next alarmed video (“next” meaning the camera that enters an 
alarmed state second) is displayed until cleared; operation continues in this manner. 
Note that alarms can be armed and disarmed individually as required. Note also that 
all alarms must be manually cleared; the presence of alarm video is not dependent 
upon the duration of the alarm input signal to the system.