Sequence Programming
EN | 51
Continue entering camera, monitor, and dwell times in this fashion until finished. If 
you only want to store the sequence for future use and then exit the programming 
mode, press Exit / Save [Prog]. Press Exit / Run [Run], to exit the programming 
mode, store the sequence into memory, and start the sequence running. The 
switcher steps through the five (5) steps in the order shown, and repeats the 
sequence when it reaches the last step. 
To program a sequence to run once through all its steps and then stop, enter the 
value 62 for the dwell time in the last step and press [Enter]. The dwell display will 
change to STP, meaning stop. To program a sequence to run once through all its 
steps and then unload itself, enter the value 63 for the dwell time in the last step, and 
press [Enter]. The dwell display will change to ULD, meaning unload. 
To edit an existing sequence, press Program Sequence [Prog], enter the existing 
sequence number, then press [Enter]. You can insert a line into a sequence by navi-
gating down to the line where inserting a new line, and press Insert Step [ON]. A 
new line identical to the one you are on is added to the next step. To delete a step, 
navigate to the line to be deleted, and press Delete Current Step [OFF]. To delete all 
steps below the line you are viewing, press Delete From Here To End [Lock]. (Be 
careful with this feature!) 
It is also possible to erase a sequence: Press Delete From Here To End [Lock] while 
on the first line of the sequence. Then press Delete Current Step [OFF]. The 
sequence will be erased, and the programming mode is automatically exited.
 
Sequence Function Summary
All programming key functions for the LTC 8555 Series are summarized in the fol-
lowing table:
Key
Description
PROG
Selects or terminates program mode
CLEAR
Clears current entry
ENTER
Stores current entry
PREV
Stores entry and move up one step
NEXT
Stores entry and move down one step; add new 
step if necessary
ON
Insert step before current step
OFF
Delete current step
UP
Move up one step
DOWN
Move down one step, if step already exists
LEFT
Move prompt left one cell
RIGHT
Move prompt right one cell
LOCK
Erase all steps after current step
RUN
Exit, store, load, and run current sequence