Bosch 8500 User Manual

Page of 104
EN | 74
Bosch Security Systems | December 13, 2005
Calibrate
]. If using the LTC 8555 Series keyboard, refer to the User Function 1 
procedure. (See Chapter 14, “User Information,” on page 38).
21.3 Video Monitor Display Checkout
1.
No video display on any monitor: Verify proper CPU operation as described 
above under Main Bay Checkout Section.
2.
No video display on some monitors: Verify operational camera is selected on 
suspect monitors. Confirm monitor is operational. Check monitor coax connec-
tions. Verify coax connection to correct monitor output on rear of main bay. 
Replace video output module.
3.
Poor video on monitor: Check monitor for proper termination. Check opera-
tion of known good camera directly to monitor.
4.
Partial or no on-screen alphanumeric display: Check user selectable bright-
ness feature (via USER 5 keyboard function) and then verify alphanumeric dis-
play has been enabled (via USER 6 keyboard function). Position the overlay 
with USER 4 function.
5.
Time and Date portion of the on-screen display alternates with “?? ?? ??”, 
and the LED on the front panel indicates a low battery condition: Replace 
CPU batteries.
21.4 Remote Receiver/Driver Functions Inoperative
1.
All receiver / drivers and functions inoperative: Verify power LED indica-
tor on Signal Distribution Unit is lit. If not, check fuses on front of main CPU 
bay power supply. Verify the Code LED indicator flickers when control is acti-
vated by the keyboard. If not, replace Signal Distribution Unit.
2.
Individual receiver/driver non-operative: Check green LED indicator on 
fuse bracket in receiver/driver box. This signifies that AC power is applied by 
the keyboard. If not, check shielded-twisted-pair cable between Signal Distribu-
tion Unit and receiver/driver box. Confirm camera address setting in receiver/
driver corresponds to same camera number as selected by the keyboard. Per-
form internal receiver/driver local test to verify operation of receiver/driver cir-
cuitry and pan/tilt/zoom wiring.
3.
AutoDome series dome cameras are not operating in a variable speed 
fashion: Verify CPU DIP switch 7 is selected for variable speed mode.
21.5 No Alarm Response
1.
No system alarms operative: Verify power LED indicator on Alarm Interface 
Unit is lit. If not, check fuses on front of main CPU bay power supply. Verify the 
Alarm LED indicator lights and the audible buzzer sounds (if enabled) only 
when an 'alarm' is applied to the unit. If not, replace Alarm Interface unit.
2.
Individual cameras/monitors not responding when alarmed: Ensure 
desired cameras are properly armed on the appropriate armed monitors in the 
system. Verify alarming device and cable to Alarm Interface unit intact.