D1260/D1260B | Owner's Manual | Part III: Advanced Commands - SERVICE MENU ? (9 + 9 + Enter) 
 
 
66 
Bosch Security Systems | 9/04 | 50410D 
 
 
If you know the point number, you can 
enter it by pressing its number key and 
then the ENTER key. 
The display will change to show the point 
that was entered. If the point is invalid the 
message “Invalid Point” or “This is not a 
valid walk point” appears. 
 
Test each point by first opening and then closing 
the door or window or other detection device. 
Check the display after testing each point. For 
interior points, walking past the device once is 
sufficient. If any point does not test correctly, 
contact your security company for service. 
2.
 
During the Walk Test you may want to see the 
points that remain untested by pressing the 
View 
untested pts>
 soft key. 
 
The display shows 
### pts untested.
  
 
Press the 
Point information>
 soft key to see 
information about specific points that have not yet 
been tested. 
The display changes to show the information for 
that point. 
 
Move through this list by pressing the 
Next
 
Point>
 soft key. 
Press the 
<Exit
 soft key to return to the 
### 
points remain to be tested.
 before continuing the 
Service Walk Test. 
 
3.
 
When all points have been tested, 
0 points 
remain to be tested
 is displayed.  
 
Press the 
<Exit
 soft key. 
The display momentarily shows 
All points have 
been tested. 
 
before returning to idle text.
 
 
Using Default Text 
This function allows the current state of the area for 3 
seconds before returning to idle text. 
1.
 
Press the 
Default Text?> 
soft key to display the 
current state of the area. 
 
2.
 
The current state of the area is displayed for 3 
seconds before returning to idle text. 
 
Using Setup 
The Setup function is accessed by pressing the 
Setup?
 
> soft key.  
The adjustable functions that are available in this menu 
are: 
 
High Brightness,