10.3 Connectors
10.3.1 Introduction
This section gives an overview of typical system 
connections with the multi channel interface and 
loudspeakers.
Connecting the mains (see section 10.3.2).
Connecting the multi channel interface (see 
section 10.3.3).
Connecting to ground (see section 10.3.4).
Connecting the amplifier channels (see 
section 10.3.5).
Connecting the local audio input (see section 10.3.6
Connecting the back-up power supply (see 
section 10.3.7)
10.3.2 Connecting to the mains
Proceed as follows to connect the basic amplifier to the 
mains:
1 Select the correct local mains voltage using the 
voltage selector on the rear of the basic amplifier (see 
table 10.1).
2 Put the correct type of fuse in the basic amplifier. 
The fuse is in the mains inlet. Note that the same 
fuse value is used for both voltage ranges.
3 Connect the mains cord to the basic amplifier. 
4 Connect the mains cord to a locally approved mains 
outlet.
The mains supply can be supervised by the basic 
amplifier (see figure 10.2, no. 9) and is available for the 
multi channel interface.
10.3.3 Connecting to the multi channel 
interface
The connection to the multi channel interface (MCI) is 
made with two Ethernet connections. The MCI 
connections have a triangle and a circle symbol (see 
figure 10.5).
table 10.1: Voltage selector and fuse
Selector
Mains voltage
V(AC)
Fuse
115
100 - 120
T6.3A H 250V 
(IEC 60127 or UL 248)
230
220 - 240
T6.3A H 250V 
(IEC 60127)
figure 10.3: Connecting mains power supply
Battery
48V
0
+
0
+
115/230V
Grounded
Signal Ground
Floating
Mains
115:
100-120V       50-60Hz
          T10A  250V
230:
220-240V       50-60Hz
          T6.3A  H  250V
On
Supervision
Mains
Battery
Caution
Do not connect the circle symbol connector of 
the multi channel interface to the triangle symbol 
connector of the power amplifier.
Caution
Always use CAT-5 modular plugs with an empty 
connector crimp part (refer to figure 10.4, part 
A). Some (pre-)assembled CAT-5 modular plugs 
have a connector crimp part that is filled with 
plastic (refer to figure 10.4, part B). These 
connectors do not give a reliable connection to 
the Ethernet connectors on the basic amplifiers 
and multi channel interfaces and can therefore 
can cause unexpected fault events. 
figure 10.4: (pre-) assembled CAT-5 modular plugs
B
A