21.2 
Controls, connectors and 
indicators
The remote call station kit (see figure 21.2) contains the 
following:
X2
Back-up supply/Control inputs - Besides 
powering the remote call station kit via the 
system network connector (X908), it can also be 
powered externally from a back-up power 
supply (see section 21.2.1). The connector also 
provides two input contact pairs.
X908
System bus - An RJ45 connector to connect 
the remote call station kit to a call station 
interface via a straight Cat-5 cable. 
X1
Keypad interface - The keypad interface is 
used to connect up to 16 keypads to the remote 
call station kit (see section 21.2.6).
X300
Microphone type selector - The 
microphone type selector is used to select either 
“dynamic” or “electret condenser” microphone 
types.
X301
Microphone - The microphone input is used 
to connect a microphone (see section 21.2.3).
X511
External Speaker - The external speaker is 
meant for listening to chimes, pre-recorded 
messages etc. (see section 21.2.5). Only chimes 
and messages activated by a PTT key of the 
remote call station or one of its keypads (see 
section 47.3.3) are played via the loudspeaker of 
the remote call station.
X501
Headset - The headset connector provides the 
possibility to connect a headset to the remote 
call station kit (see section 21.2.2).
X107
Control input/outputs - The control input 
and five control outputs are used as 
replacement for the PTT key and LEDs on the 
PRS-CSR Remote Call Station (see section 
21.2.4).
Caution
Do not connect the connector X908 to any 
Telecom or Ethernet network. This connection is 
dedicated for PRS-CSI only.
figure 21.2: Component side
8
1.
.
.
.
.
X908
X2
X301
X107
1
6.
.
.
.
.
X511
6
1.
.
.
.
.
X501
6
1.
.
.
.
.
X1
16
15
2
1
.
.
.
.
.
.
.
.
.
.
.
.
.
.
1
2
13
14
.
.
.
.
.
.
.
.
.
.
.
.
.
.
8
7
2
1
.
.
.
.
X300
1
3.