Bosch 3.5 User Manual

Page of 498
Bosch Security Systems | 2011-02
Praesideo 3.5 | Installation and User Instructions | 6 | Installation Accessories
en | 277
27.3 Wiring
See figure 27.4 for details about the wires inside the 
extension cables.
27.4 Custom-made 
cables
Use LBB4418/00 Cable-connector Tool Kit to create 
custom-made cables out of LBB4416/00 Network 
Cables and LBB4417/00 Network Connectors.
27.5 Technical 
data
figure 27.4: Cable details
table 27.2: Cable details
Number
Signal
1
Protective cloth
2
Insulation
3
Outer sheet
4
Stranded wire
5
Optical fiber
7±0.1
3
2
1
5
4
Insulation:
LSZH (low smoke/zero halogen), black
Outer diameter:
7 mm
Power supply wires (2):
Copper, stranded 1 mm
2
, red and brown insulation, 
resistance < 0.018 ohm/m
Optical fibers (2):
• PMMA, 1 mm diameter including cladding 2 mm 
diameter (black)
• Numeric aperture: 0.5
• optical attenuation < 0.17 dB/m @ 650 nm
• bending loss < 0.5 dB (r = 20 mm, 90°), according 
to JIS C6861
Temperature range:
-40 to +65 °C
Pull force:
max. 150 N
UL-compliancy:
UL444 (60 °C/60 V),
Flame retardant:
according to IEC 60332-1 / 60 s
Halogen level:
according to IEC 60754-2, pH > 4.3 and 
conductivity < 10 uS/mm
Smoke level:
according to IEC 61034-2, light transmittance > 60%