31.5 
Maximum cable length
The maximum length of all optical fibers together (both 
POF and GOF) in the system depends on the number of 
nodes in the system. Each piece of equipment has been 
assigned a number of nodes.
The graph (see figure 31.5) shows the relation between 
the number of nodes in the system and maximum 
optical fiber length in the system.
table 31.2: Nodes
Type no.
Description
Nodes
LBB4402/00
Audio Expander
1
LBB4404/00
CobraNet Interface
1
PRS-NSP
Network Splitter
1
PRS-FIN(S)
PRS-FINNA
Fiber Interface
Fiber Interface
1
0/1
PRS-1P500
PRS-2P250
PRS-4P125
LBB4428/00
Power Amplifier 1x500 W
Power Amplifier 2x250 W
Power Amplifier 4x125 W
Power Amplifier 8x60 W
1
1
1
2
LBB4430/00
Call Station Basic
1
LBB4432/00
Call Station Keypad
0
PRS-CSNKP
Numeric Keypad
0
LBB4433/00
Call Station Kit
1
LBB4434/00
Call Station Keypad Kit
0
PRS-CSI
Call Station Interface
1
PRS-CRF
Call Stacker
1
PRS-16MCI
Multi Channel Interface
1
PRS-NCO-B
Network Controller
3
Note
A system may not contain more than 63 nodes.
Note
The PRS-FINNA counts as 0 nodes for the 
system limit of 63 nodes, but as 1 node for the 
maximum optical fiber length. Therefore, the 
dashed part of the line is only applicable to 
systems with PRS-FINNA Fiber Interfaces.
figure 31.5: Maximum optical fiber length vs. number of nodes
850
1050
1150
950
750
1250
1350
1450
1550
1650
1750
1850
1950
2050
2150
Max
imum cable length (
m
)        
650
5
0
10
15
20
25
Number of nodes
30
35
40
45
50
55
60
65
70
75
80