52
General events list
General events in alphabetical order:
Event message:
Amplifier resumes operation
Originator:
Main power amplifier that resumes operation.
Extra information:
Serial number and name of the spare power amplifier.
Description:
Logs the switch of a spare power amplifier to a main 
power amplifier.
Recommended action:
----
Event message:
Amplifier spare switch
Originator:
Main power amplifier that stops operating.
Extra information:
Serial number and name of the spare power amplifier.
Description:
Logs the switch of a main power amplifier to a spare 
power amplifier.
Recommended action:
Check the fault events of the main power amplifier and 
try to solve these faults.
Event message:
Call logging events discarded due to logging queue 
overflow
Originator:
----
Extra information:
----
Description:
The logging of call events is suspended due to an 
overflow of the input queue inside the network 
controller. This event is not shown on the display of 
the network controller.
Recommended action:
Make less overriding calls.
Event message:
Device connected via Open Interface
Originator:
Open interface client that connects.
Extra information:
----
Description:
Logs the connection of an open interface client to the 
system.
Recommended action:
----
Event message:
Device disconnected via Open Interface
Originator:
Open interface client that disconnects
Extra information:
----
Description:
Logs the disconnection of an open interface client 
from the system.
Recommended action:
----