Bosch 3.5 User Manual

Page of 498
Bosch Security Systems | 2011-02
Praesideo 3.5 | Installation and User Instructions | 11 | Optional Software
en | 448
56.5 Main 
window
56.5.1 Opening the main window
Proceed as follows:
1 Double click on the Logging Server icon (see figure 
56.2). A screen similar to the one in figure 56.4 
appears.
56.5.2 Status messages
The main window displays the status of the Logging 
Server
.
Note
When server authentication (see section 56.7.5
is enabled, the Logging Server asks for a user 
name and a password.
figure 56.4: Main window
Message:
The Logging Server is OK.
Description:
The Logging Server operates correctly.
Recommended action:
----
Message:
Logging Server has no connection with <system>
Description:
There is no connection with the specified system.
Recommended action:
Make sure that the specified system is running and 
that the specified system has an Ethernet connection 
with the Logging Server.
Message:
Network controller <system> refused connection due 
to incorrect user name or password.
Description:
It is not possible to connect to the specified system, 
because the network controller authentication failed.
Recommended action:
Make sure the specified system knows the user name 
and password of the Logging Server (see section 
Message:
The Logging Server options are changed. Restart the 
Logging Server to use the changed settings.
Description:
The configuration settings of the Logging Server were 
changed. The changed settings are not used until the 
Logging Server is restarted.
Recommended action:
Restart the Logging Server to use the new settings.