58.4 Start
The PC automatically starts the PC Call Server as a 
service when Windows is started.
Important events will be logged to the Windows event 
log:
Startup and shutdown of the service
Error messages about license validity
Abnormal (fatal) errors that cause the service to shut 
down
58.5 Configuration
Use the PC Call Server Configuration Client (see 
chapter 59) to configure the PC Call Server.
58.6 Firewall
The PC Call Server and the related programs PC Call 
Station Client and PC Telephone Interface Client use 
port TCP 9452. In case a firewall is used, this port 
should be enabled. If needed, this port number can also 
be changed by editing the XML file  <application 
name>.exe.config,
 for each application separately. These 
files are in the install path of the applications.
Note
Make sure that the Windows options 
Network 
discovery and File sharing are activated on the 
system where the PC Call Server is running. If 
not, the connection from a PC Call Server 
Configuration Client, a PC Call Station Client or 
a PC Telephone Interface Client may fail. 
Access to these options differ between 
Windows versions:
In Windows XP, no actions are required. 
In Windows Vista, these options can be set via 
Start > Control Panel > Network and Internet > 
Network and Sharing Center > Sharing and 
Discovery.
 Then turn on Network discovery and turn 
on 
File sharing.
In Windows 7, these options can be set via 
Start 
> Control Panel > All Control Panel Items > 
Network and Sharing Center > Change advanced 
sharing settings
. Then select Turn on network 
discovery
 and select Turn on file and printer 
sharing