Desa Tech CRL3124PA/NA User Manual

Page of 36
www.desatech.com
113097-01L
23
INSPECTING bURNERS
•  turn  heater  off  (see  To  Turn  Off  Gas  to 
Appliance,  page  20  [manually-controlled 
models] or page 22 [thermostat-controlled 
models])
•  see Troubleshooting, page 25
Note: The pilot flame on natural gas units will 
have a slight curve, but flame should be blue 
and have no yellow or orange color.
BURNER PRIMARY AIR HOLES
Air is drawn into the burner through the holes 
in  the  fitting  at  the  entrance  to  the  burner. 
These holes may become blocked with dust, 
lint or pet hair. Periodically inspect these holes 
for  any  blockage  and  clean  as  necessary. 
Blocked air holes will create soot.
MAIN BURNER
Periodically inspect all burner flame holes with 
the  heater  running. All  slotted  burner  flame 
holes should be open with yellow flame pres-
ent. All round burner flame holes should be 
open with a small blue flame present. Some 
burner flame holes may become blocked by 
debris  or  rust,  with  no  flame  present.  If  so, 
turn off heater and let cool. Remove blockage. 
Blocked burner flame holes will create soot.
Figure 33 - Correct Pilot Flame Pattern
Figure 34 - Incorrect Pilot Flame Pattern
Thermocouple
Pilot Burner
Thermocouple
Pilot Burner
CLEANING AND MAINTENANCE
Check  pilot  flame  pattern  and  burner flame 
patterns often.
PILOT FLAME PATTERN
Figure 33 shows a correct pilot flame pattern. 
Figure 34 shows an incorrect pilot flame pat-
tern. The incorrect pilot flame is not touching 
the thermocouple. This will cause the thermo-
couple to cool. When the thermocouple cools, 
the heater will shut down.
If  pilot  flame  pattern  is  incorrect,  as  shown 
in Figure 34
  WARNING:  Turn  off  heater 
and let cool before cleaning.
  CAUTION:  You  must  keep 
control areas, burner and circu-
lating air passageways of heater 
clean.  Inspect  these  areas  of 
heater  before  each  use.  Have 
heater  inspected  yearly  by  a 
qualified service person. Heater 
may need more frequent clean-
ing  due  to  excessive  lint  from 
carpeting, bedding material, pet 
hair, etc.
  WARNING:  Failure  to  keep 
the  primary  air  opening(s)  of 
the burner(s) clean may result in 
sooting and property damage.
BURNER INjECTOR HOLDER AND 
PILOT AIR INLET HOLE
The primary air inlet holes allow the proper 
amount of air to mix with the gas. This pro-
vides  a  clean  burning  flame.  Keep  these 
holes  clear  of  dust,  dirt,  lint  and  pet  hair. 
Clean  these  air  inlet  holes  prior  to  each 
heating season. Blocked air holes will create 
soot. We recommend that you clean the unit 
every  three  months  during  operation  and 
have heater inspected yearly by a qualified 
service person.
We also recommend that you keep the burner 
tube and pilot assembly clean and free of dust 
and dirt. To clean these parts we recommend 
using compressed air no greater than 30 PSI. 
Your local computer store, hardware store or 
home center may carry compressed air in a 
can. If using compressed air in a can, please 
follow the directions on the can. If you don’t 
follow directions on the can, you could dam-
age the pilot assembly.