DMX Primer 
 
 
 
There are 512 channels in a DMX connection. A fixture capable of receiving DMX will require 
one or a number of sequential channels. The user must assign a starting address on the fixture 
that indicates the first channel reserved in the controller. There are many different types of DMX 
controllable fixtures and they all may vary in the total number of channels required. Choosing a 
start address should be planned in advance. Channels should never overlap. If they do, this will 
result in erratic operation of the fixtures whose starting address is set incorrectly. You can 
however, control multiple fixtures of the same type using the same starting address as long as 
the intended result is that of unison movement or operation. In other words, the fixtures will all 
respond exactly the same.  
 
DMX fixtures are designed to receive data through a daisy chain. A daisy chain connection is 
where the DATA OUT of one fixture connects to the DATA IN of the next fixture. The order in 
which the fixtures are connected is not important and has no effect on how a controller 
communicates to each fixture. Use an order that provides for the easiest and most direct 
cabling. Connect fixtures using shielded two conductor twisted pair DMX data cable with three 
pin XLR male to female connectors. The shield connection is pin 1, while pin 2 is Data Negative 
(S-) and pin 3 is Data positive (S+). 
 
 
Fixture Linking (Daisy Chain) 
 
 
 
You will need a daisy chain to run light shows of one or more fixtures using a DMX controller or 
to run synchronized shows on two or more fixtures set to a master/slave operating mode. The 
combined number of channels required by all the fixtures on a daisy chain determines the 
number of fixtures the data link can support.  
 
 
 
To comply with the EIA-485 standard, do not connect more than 32 fixtures on one daisy 
chain. Connecting more than 32 fixtures on one daisy chain without the use of a DMX 
optically-isolated splitter may result in deterioration of the digital DMX signal.  
 
Maximum recommended cable distance: 500 m (1640 ft)  
Maximum recommended number of fixtures on a daisy chain: 32 
 
 
Data Cabling 
 
 
 
To link fixtures together you must obtain data cables. You can purchase CHAUVET® certified 
DMX cables directly from a dealer/distributor or construct your own cable. If you choose to 
create your own cable please use data-grade cables that can carry a high quality signal and are 
less prone to electromagnetic interference. 
 
 
DMX Data Cable 
 
 
 
Use a Belden© 9841 or equivalent cable which meets the specifications for EIA RS-485 
applications. Standard microphone cables cannot transmit DMX data reliably over long 
distances. The cable must have the following characteristics: 
 
Type: 
shielded, 2-conductor twisted pair 
Maximum capacitance between conductors: 
30 pF/ft 
Maximum capacitance between conductor and shield: 
55 pF/ft 
Maximum resistance: 
20 ohms/1000 ft 
Nominal impedance: 
100 ~ 140 ohms