Design Dynamics VF-24P-MHD User Manual

Page of 28
www.fmiproducts.com
116986-01H
19
Thermocouple
Thermocouple
Figure 22 - Incorrect Pilot Flame Pattern 
(Natural Gas Pilot Shown)
Figure 21 - Correct Pilot Flame Pattern 
(Natural Gas Pilot Shown)
BURNER FLAME PATTERN
Figure  23  shows  correct  burner  flame  pat-
tern.
NOTICE: Do not mistake orange 
flames with yellow tipping. Dirt 
or other fine particles are burned 
by heater, causing brief patches 
of orange flame.
If burner flame pattern is incorrect, as shown 
in Figure 24
•  turn appliance off (see To Turn Off Gas to 
Appliance, page 18)
•  see Troubleshooting, page 21
Figure 23 - Correct Burner Flame Pattern 
Figure 24 - Incorrect Burner Flame 
Pattern 
Blue & Bright 
Yellow Flames
Orange 
Flames
INsPeCTING BURNeRs
Check  pilot  flame  pattern  and  burner flame 
patterns often.
PILOT FLAME PATTERN
Figure 21 shows a correct pilot flame pattern. 
Figure 22 shows an incorrect pilot flame pat-
tern. The incorrect pilot flame is not touching 
the  thermocouple.  When  the  thermocouple 
cools, the heater will shut down.
If  pilot  flame  pattern  is  incorrect,  as  shown 
in Figure 22
•  turn heater off (see To Turn Off Gas to Ap-
pliance, page 18)
•  see Troubleshooting, page 21
Note: The pilot flame on natural gas units will 
have a slight curve, but flame should be blue 
and have no yellow or orange color.