State  of  Massachusetts:  The  installa-
tion must be made by a licensed plumber 
or  gas  fitter  in  the  Commonwealth  of 
Massachusetts.
Sellers  of  unvented  propane  or  natural 
gas-fired supplemental room heaters shall 
provide to each purchaser a copy of 527 
CMR 30 upon sale of the unit.
Vent-free  gas  products  are  prohibited  for 
bedroom and bathroom installation in the 
Commonwealth of Massachusetts.
Hand-Held 
Remote Control
Chassis Assembly
Control Valve with 
Remote Receiver 
Module
Log Set 
Assembly
loCal Codes
Install  and  use  heater  with  care.  Follow  all 
local  codes. In the absence  of local  codes, 
use  the  latest  edition  of  The  National  Fuel 
Gas Code ANSI Z223.1/NFPA 54
*.
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
PRodUCT FeaTURes
OPERATION
This  heater  is  clean  burning.  It  requires  no 
outside venting. There is no heat loss out a 
vent or up a chimney. Heat is generated by 
realistic  flames  and  glowing  ceramic  logs/
coals. This  heater  is  designed  for  vent-free 
operation  with  flue  damper  closed.  It  has 
been tested and approved to ANSI Z21.11.2 
standard for unvented heaters. State and lo-
cal codes in some areas prohibit the use of 
vent-free heaters.
SAFETY PILOT
This heater has a pilot with an Oxygen Deple-
tion Sensing (ODS) safety shutoff system. The 
ODS/pilot is a required feature for vent-free 
room  heaters.  The  ODS/pilot  shuts  off  the 
heater if there is not enough fresh air.
REMOTE IGNITION AND CONTROL
This  gas  log  set  has  a  battery  powered 
electronic  remote  ignition  and  control.  This 
system requires no matches or other source 
to light log set.
aIR FoR CoMBUsTIoN aNd VeNTIlaTIoN
 WARNING: This heater shall not be installed in a room or space 
unless the required volume of indoor combustion air is provided by 
the method described in the National Fuel Gas Code, ANSI Z223.1/
NFPA 54, the International Fuel Gas Code, or applicable local codes. 
Read the following instructions to insure proper fresh air for this 
and other fuel-burning appliances in your home.
Today’s homes are built more energy efficient 
than ever. New materials, increased insulation 
and new construction methods help reduce heat 
loss in homes. Home owners weather strip and 
caulk  around  windows  and  doors  to  keep  the 
cold air out and the warm air in. During heating 
months,  home  owners  want  their  homes  as 
airtight as possible.