Monessen Hearth DLX28 User Manual

Page of 40
14
14D2099
Heater in 
Fireplace or 
Firebox
Heat 
Resistant
Material
10"
8"
6"
2
1
/
2
"
4
1
/
8
"
6
1
/
2
"
8"     14"    20
1
/
2
"   24
5
/
8
"  28"
3
7
/
8
Heater in 
Fireplace or 
Firebox
Heat 
Resistant
Material
Hood
10"
12"
8"
6"
2
1
/
2
"
8"    14
1
/
2
"  18
5
/
8
"   22
1
/
2
"   26"
Example:
A mantel may project from the wall a maximum of 2
1
/
2
" at a mini-
mum of 8" above the opening, and a maximum of 6" at a minimum
of 14
1
/
2
" above the opening.
CLEARANCES 
AND
 HEIGHT REQUIRMENTS
Figure 7 - Minimum Mantel Clearance with No Hood — DLX/GLX 18
Figure 8 - Minimum Mantel Clearance with Hood — All Models
Example:
The bottom of the mantel may project from the wall a maximum of
2
1
/
2
" at a minimum of 14" above the opening. The top shelf of the
mantel may project a maximum of 6" at a minimum of 20
1
/
2
" above
the opening.