TROUBLESHOOTING
Continued
POSSIBLE CAUSE
1. Control knob not fully pressed in
2. Control knob not pressed in 
long enough
3.  Equipment shutoff valve not 
fully open
4. Thermocouple  connection 
loose at control valve
5. Pilot flame not touching ther-
mocouple, which allows ther-
mocouple  to  cool,  causing 
pilot  flame  to  go  out.  This 
problem could be caused by 
one or both of the following:
  A) Low gas pressure
  B) Dirty or partially clogged 
ODS/pilot
6. Thermocouple damaged
7. Control valve damaged
8. Safety  interlock  system  has 
been  triggered  (thermostat 
models only) 
 
1. Burner orifice(s) is clogged
2. Inlet gas pressure is too low
1. Manifold pressure is too low
2. Burner orifice(s) is clogged
1. Burner orifice(s) is clogged or 
damaged
2. Burner damaged
3. Gas regulator defective
1. Plaque damaged
2. Inlet gas pressure is too low
3. Control  knob  set  between 
locked positions
1. Residues from manufacturing 
processes
1. Metal expanding while heating 
or contracting while cooling
REMEDY 
1. Press in control knob fully
2.  After ODS/pilot lights, keep con-
trol knob pressed in 30 seconds
3. Fully open equipment shutoff 
valve
4. Hand tighten until snug, then 
tighten 1/4 turn more
5. A)  Contact  local  natural  or 
propane/LP gas company
  B)  Clean  ODS/pilot  (see 
Cleaning  and  Maintenance
page 18) or replace ODS/pilot 
assembly 
6. Replace pilot assembly
7. Replace control valve
8. Wait one minute for safety in-
terlock system to reset. Repeat 
ignition operation
1. Clean burner orifice(s) (see Clean-
ing and Maintenance, page 18) 
or replace burner orifice(s)
2. Contact local natural or pro-
pane/LP gas company
1. Contact local natural or pro-
pane/LP gas company
2. Clean burner orifice(s) (see Clean-
ing and Maintenance, page 18) 
or replace burner orifice(s)
1. Clean burner orifice(s) (see Clean-
ing and Maintenance, page 18) 
or replace burner orifice(s)
2. Replace burner
3. Replace gas regulator
1. Replace burner
2. Contact local natural or pro-
pane/LP gas company
3. Turn  control  knob  until  it 
locks at desired setting
1. Problem will stop after a few 
hours of operation
1. This is common with most heat-
ers. If noise is excessive, contact 
qualified service person
OBSERVED PROBLEM
ODS/pilot  lights  but  flame 
goes out when control knob is 
released
Burner(s)  does  not  light  after 
ODS/pilot is lit
Delayed ignition of burner(s)
Burner backfiring during com-
bustion
Burner  plaque(s)  does  not 
glow
Slight  smoke  or  odor  during 
initial operation
Heater produces a clicking/tick-
ing noise just after burner is lit 
or shut off