Monessen Hearth GLX18 User Manual

Page of 40
12
14D2099
Measure 
this
distance
Heater in 
Fireplace or 
Firebox
Heat 
Resistant
Material
CLEARANCES and HEIGHT REQUIREMENTS
Heat resistant material (minimum requirements) with no wooden mantel or other combustible projection:
To install the gas logs into a fireplace with no wooden mantel, shelf or other combustible projection above the fireplace
opening, measure the heat resistant material height, per Figure 4, then refer to TABLE A.
Heat resistant materials such as slate and marble must be at least 1/2" thick. Sheet metal should not be installed onto
combustible material.
IMPORTANT:
 If you cannot meet these minimum clearances you must operate the heater with chimney flue damper open.
Refer to “INSTALLING VENTED APPLICATIONS” found on page 17.
Figure 5 - Measuring Heat Resistant Material
HEAT RESISTANT
REQUIREMENTS FOR SAFE INSTALLATION
MATERIAL
MEASUREMENT
DLX18/GLX18
DLX/GLX 24 AND 28
All Models
All Models
12" or more
Hood not required.
Hood not required.
8" to less than 12"
Hood not required.
Extend heat resistent material to 12"
or install hood. 
See Figure 5.
Less than 8"
Extend heat resistant
Extend heat resistant material to at
material to at least 8"
least 8" and install hood. 
See Figure
5. OR, extend heat resistant material
to a height of at least 12".
TABLE A - Heat Resistant Material Requirements with no Mantel or Combustible Projection