Roberts Gorden TF-Series User Manual

Page of 44
ROBERTS GORDON
®
  T F-S
E RIE S
 S
U BMI TT AL
 S
HEE T
© 2004 Roberts-Gordon
APPLI CAT IONS,  ENGIN EE RING AND DE TAI LE D GUIDANCE  ON SYST EMS DE SI GN, I NSTALL ATION  AND PRODUCT  PE RFORMANCE I S AVAIL ABL E  UPO N REQUE ST. ROBERTS GO RDON
®
 PRODUCTS ARE  TO  BE  
INSTAL LE D ONLY I N ACCOR DANCE  WIT H L OCAL  L AW S,  CODES AND RE GULAT IONS, AND  ONLY BY A CONTRACTO R QUALI FIE D IN  THE  INST AL LAT ION AND  SE RVICE  OF GAS-F IRE D HEAT ING E QUIPMEN T.
Frame Shield Installation
Reflector Side Extension Installation 
Shield
Descr ipti on
Part Number
Deco Grille Shield
01365900
NOTE: If the Decorative Grille system is to
be installed in an area with considerable
air movement, it is recommended that one
#8 x 3/8 (3.9 x 9.5mm) sheet metal screw
be installed per reflector extension to
prevent it from blowing over.
A
Reflector Side
Extension
Cut Relief Notches for Tube
and Reflector Hangers
Insert Screw
here
Distance "A"
Extension
Mi nimum
Maximum
Par t No.
Width
2" (4 cm)
6" (15 cm)
01370408
8" (20  cm)
6" (15 cm)
10" (26 cm)
01370412
12" (30 cm)
10" (26 cm)
14" (37 cm)
01370416
16" (40 cm)
Description
Part Number
Reflector Side Ext ension
01370412