GAS PIPING
FIGURE 1: Gas Connection with Stainless Steel Flex Connector 
Hold gas nipple securely
with pipe wrench when
attaching the flex gas
connector.
Failure to follow these
instructions can result in
product damage.
Burner
2" (5 cm)
Stainless
Steel Flex
Gas Connector
Shut-Off Valve
(included
with connector)
3/4" NPT Pipe
Shut-Off Valve must be parallel to
burner gas inlet. The 2" (5 cm)
displacement shown is for the cold
condition. This displacement may
reduce when the system is fired.
12"
(30 cm)
45°
90°
45°
90° Pipe Elbow (not supplied)
Descri ption
Part Number
1/2” Flex G as Line
91412200
3/4” Flex G as Line
91412203