Procom ML300TGA User Manual

Page of 21
        1 1
Figure 17 - Control  Knob  in  The
OFF  Position
Figure 18 - Pilot
LIGHTING
INSTRUCTIONS
1 .     S T O P !     R e a d       t h e     s a f e t y
     information  on  the  side of
       heater.
2.  Check  that  gas  supply  to
       heater  is  on.
3.  Push  in  gas  control  knob
       slightly  and  turn  clockwise    
      to the OFF position.
NOTE:   Knob  cannot  be  turned from
"
PILOT
"
  to  
"
OFF
"
  unless knob  is
p u s h e d     i n     s l i g h t l y .   D o     n o t
force.
4.   Wait five (5) minutes  to  clear
      out   any   air. Then   smell  for
       gas,  including  near  the  floor.
        If      you      smell     gas,    STOP!
       Follow   
"
B
"
     in     the     safety
        information  on  the  side of  the
       heater.  If   you   do   not   smell
       gas,  go  to  the  next  step.
5.    Push     in    gas   control   knob
        slightly                  and                 turn
       counterclockwise     
      to
      
"
PILOT/IGN
"
  and  depress  for
        five(5) seconds
NOTE:   The  first  time  that  the
heater   is  operated  after  connecting
the   gas  supply ,  the   control   knob
should  be  depressed for  about  thirty
(30) seconds.  This will   allow  air  to
bleed   from  the  gas  system.
6.    With  control  knob  pressed  in,
       push  down  and   release   the
     ignitor button. This  will  light
       pilot. If  needed,   keep    pressing
     ignitor button until pilot  lights.
NOTE:  If  pilot  does  not  stay  lit,refer
to  Troubleshooting,  pages 14 through
16.   Also  contact  a  qualified  service
person  or  gas   supplier   for  repairs.
Until   repairs are   made,   light   pilot
with   match. To light  pilot  with match,
see Manual   Lighting   Procedure.
7.   Keep  control  knob  pressed  in
     for  thirty  (30)  seconds  after
       lighting       pilot.         After       30
       seconds,  release  control  knob.
 
If   control   knob  does   not   pop
     up  when  released,  contact  a
      qualified     service    person    or
       gas  supplier  for  repairs.
NOTE:   If  pilot  goes  out,  repeat
steps 3 through 7. Wait one (1)
minute  before  lighting  pilot  again
8.   Turn             control            knob
       counterclockwise       
          to
      desired    heating    Level.   The
      main  burner  should  light.  Set
      control  knob  to  any  heat  level
       between  HI  and  LO.
THERMOSTAT
CONTROL
OPERATION
OPERATING     YOUR     HEATER
The  thermostatic  control  used  on
these  models  differs from  standard
thermostats.  Standard   thermostats
simply  turn  on  and  off  the  burner.The
thermostat  used  on  this  heater
senses  the  room   temperature.  The
thermostat     adjusts     the    amount
of    gas    flow     to     the       burner.
This  increases  or  decreases   the
burner  flame height.  At  times  the  room
may exceed  the  set temperature.  If  so,
the  burner  will  shut  off.  The  burner
will  cycle  back  on  when room  tem-
perature  drops   below  the set
temperature. The    control knob  can  be
set  to  any  heat  level between  HI and
LO. Selecting  the HI  setting  will  cause
the  burner  to remain  fully  on  without
modulating  down  in  most cases.
NOTE:    the   thermostat sensing        bulb
measures  the  temperature  of air  near
the  heater  cabinet. This may  not  al-
ways   agree   with   room  temperature
(depending  on  housing  construction.
installation  location,  room  size,      open
air  temperatures, etc.). frequent  use  of
your  heater  will   let  you  determine
y o u r     o w n     c o m f o r t     l e v e l s .
 
  TO TURN OFF     
GAS TO APPLIANCE
Shutting  Off  Heater
1.   Turn  control  knob  clockwise
         
  to  the  OFF  position.
2.     Turn  off  all   electric   power   to
       the  appliance  if  service  is  to
        be  performed.
SHUTTING OFF BURNER ONLY
(PILOT  STAYS  LIT)
Tu r n   c o n t r o l   k n o b   c l o c k w i s e  
to  the  PILOT/IGN  position.
MANUAL LIGHTING
PROCEDURE
1.     Remove  lower  front  panel (see
        Figure 7 page 7).
2.   Follow   steps   1   through  5
        under Lighting Instructions.
3.     With   control   knob   pressed  in,
        strike    match.    Hold   match    to
         pilot until pilot lights.
4.     Keep  control  knob  pressed  in
      for 30  seconds  after lighting
        pilot.  After  30  seconds, release
      control   knob.  Follow   step  8
        under  Lighting  Instructions.
5.     Replace   lower  front   panel.