INSTALLATION
Figure 8 - Mounting  Bracket
Clearances
Figure 7 - Removing  Lower Front
Panel  Of  Heater
Figur  4 -Mounting  Clearances As
Viewed  From  Front  Of  Heater
         WARNING:   Maintain  the
minimum  clearances  shown
i n     F i g u r e   4 .     I f     y o u   c a n ,
provide   greater   clearances   from
floor,   ceiling,  and   joining  wall.
      IMPORTANT:   Vent-free
heaters  add  moisture  to   the
air.  Although  this  is  beneficial,
installing  heater  in  rooms
without  enough  ventilation  air
may   cause  mildew  to    form
from  too  much  moisture.  See
Fresh  Air  for Combustion and
Ventilation
,  page s 4 and 5.
INSTALLING THERMOSTAT
SENSING BULB
For ML300TGA
1. Pull out the sensing  bulb  from the
    two  clips  located  in  the  shippng
    position according to the direction
   as shown by the arrow. There is no
    need to take out  the two bulb clips.
2. Take  out  the  bulb  clip  from  the
     hardware package and insert  it into
      the square hole and then insert the
     sensing bulb into the bulb clip (see
     Figure 5).
FASTENING HEATER TO WALL
Mounting  Bracket
The  mounting   bracket   is  located   on
back panel of heater(see figure 6). It has
been  taped  there for shipping. Remove
mounting bracket  from  back  panel.
Removing Lower Front  Panel Of
Heater
1.  Remove  two  screws  near bottom
     corners  of  lower front panel
2.  Pull  bottom of  lower front  panel
     forward, then  down (see Figure 7).
Methods  For  Attaching   Mounting
Bracket  To  Wall
Only  use  last  hole  on  each  end    of
mounting  bracket  to  attach    bracket   to
wall. These  two  holes  are 16 inches
apart from their centers.Attach mounting
bracket  to  wall  only in one of  two ways:
1.    Attaching  to  wall  stud
2.    Attaching  to  wall  anchor
Attaching  to  Wall  Stud:  This method
provides  the  strongest       hold.   Insert
mounting   screws through  mounting
bracket  and  into  wall  studs.
Attaching  to  Wall  Anchor: This
method  allows  you  to attach
mounting  bracket  to  hollow  walls
(wall areas between  studs) or to
solid   walls  (concrete  or  masonry).
Decide   which   method   better
suits  your  needs.  Either  method
will  provide  a  secure   hold  for  the
mounting  bracket.
Marking  Screw  Locations
1.  Tape  mounting  bracket  to  wall
where  heater  will  be  located.
Make  sure  mounting  bracket  is
level.
2.  Mark  screw  locations  on
wall (see  Figure  8).
Note:  Only  mark  last  hole  on
each  end  of  mounting  bracket.
Insert  mounting  screws  through
these  holes  only.
3.   Remove  tape and  mounting
bracket  from  wall.
          WARNING:           Maintain
minimum   clearances  shown  in
Figure 8.  If   you   can,   provide
greater   clearances   from   floor
and   joining   wall.
Model  ML300TGA, ML300HGA
Figure 5 - Moving Thermostat
Sensing Bulb
Figure  6 -Mounting  Bracket