Gas-Fired Products 100 User Manual

Page of 53
Form #43343530 
 
 
July 08 
–47– 
 
23.2) 
REMOVAL OF GAS VALVE AND MANIFOLD ASSEMBLY 
 
Step 1
Remove side
access panel.
Loosen screws from
manifold clamp and
burner assembly.
Step 3
Open hinged access
panel and disconnect
wires from gas valve.
Step 4
Remove (6) screws from
end panel. Rotate gas valve
and manifold assembly
slightly counter-clockwise
and slide out from housing.
Step 2
 
23.3) 
AIR SWITCH PRESSURE CHECK 
 
P1
+
P2
-
P1
+
P2
-
0.65” WC
+
-
Connector
Tees
Air
Switch
Digital or Inclined
Water Manometer
scale 0-2”w.c.
Temporary 1/4” ID Silicone /
plastic tubing for pressure
test.
Common “C”
Normally
open “NO”
 
 
1.  Open hinged access panel. 
2.  Add tubing to connect the air switch tubing P1 + and P2 - with the connector tees and the probes P1+ and P2+.