FMI GL36ST User Manual

Page of 20
www.fmiproducts.com
55173H
6
Figure 3 - Clearances from Top View
Figure 4 - Clearances from Side View
MANTEL CLEARANCES
Woodwork, such as wood trims, mantels and other 
combustible materials, should not be placed within 
7" of the opening of this appliance (see Figure 
5).  Combustible  material  above  the  fireplace 
projecting more than 1 
1
/
2
" from the appliance’s 
front face must not be less than 12" from the ap-
pliance opening.
Figure 5 - Mantel Clearances
FIREPLACE 
INSTALLATION
CLEARANCES
Minimum clearances to combustibles are:
•  Fireplace flanges to studs . . . . . . . . . . . . . . 0"
•  Fireplace back/sides . . . . . . . . . . . . . . . . . . 1"
•  Fireplace spacers to framing . . . . . . . . . . . . 0"
•  Openings to perpendicular wall . . . . . . . . . 4"
•  End glass to facing wall . . . . . . . . . . . . . . 12"
•  Side glass to facing wall . . . . . . . . . . . . . . 36"
•  Bottom of fireplace to floor or platform . . . 0"
•  “B” vent surfaces . . . . . . . . . . . . . . . . . . . . 1"
•  Top of fireplace opening to ceiling . . . . . . 35"
See Figures 3 and 4.
 CAUTION:  Do  not  block
required  air  spaces  with  insu-
lation or any other material. Do
not  obstruct  effective  opening
of  appliance  with  any  type  of
facing material.
In selecting a location, the following precautions 
must be observed:
1.  Do not connect this appliance to a chimney 
system  used  for  a  solid  fuel  burning  fire-
place.
2.  Install in an area providing ventilation and 
adequate combustion air.
3.  Due to high temperatures, do not locate this 
appliance in high traffic areas or near furniture 
and draperies.
4.  Never obstruct the front opening of the appli-
ance or the flow of combustion and ventilation 
air. Keep control compartments accessible.
5.  DO NOT locate in the vicinity where gasoline 
or other flammable liquids may be stored. The 
appliance area must be kept clear and free 
from these combustible materials.
SELECTING LOCATION
Continued
1" (22 mm) Minimum
Clearance to Combustibles
1" (22 mm) Minimum
Clearance from Pipes
 to Combustibles
4" (102 mm) Min. from the Perpendicular
Side Wall to the Fireplace Opening (Typ.)
6" O.D.
(152 mm)
19"
(483 mm)
11 
3
/
8
"
(289 mm)
22 
3
/
4
"
(578 mm)
22 
1
/
4
"
(565 mm)
35" (889 mm) Min.
to Effective Opening 
to Ceiling
Doublewall
6" B-Vent
1" (25 mm) Min. Clearance
from Pipes to Combustibles
Do Not Pack Space 
Between Spacer with 
Any Type of Insulation
0" to 
Floor
Note: Mantel clearances apply
to both sides of the applliacne.
Header
Drywall
Fireplace Top
12 
1
/
4
"
(Ref.)
6" (Ref.)
33°
12" Min.
7" Min.
to Effective
Opening
3" Nom.
1
/
2
" Max.
Combustible
Materials