Dimplex BFH24T User Manual

Page of 4
 
 
 
 
 
 
 
    
Installation & Operating Instructions 
 
Base 
Unit 
Fan 
Heater 
        
 
Model: BFH24T, BFH24TB & BFH24TS
                                 
08/17171/7   Issue 7  APR ‘05
 
 
IMPORTANT: These instructions should be read and carefully retained by the user. 
 
Safety Warnings 
• 
 
DO NOT COVER OR OBSTRUCT the air inlet or outlet grille. 
•   ENSURE THE APPLIANCE IS EARTHED. 
Do Not place heater immediately below a socket outlet. 
• 
• 
• 
• 
• 
• 
• 
• 
If the appliance is covered, there is a risk of fire. 
Do not use this heater with young children unattended. 
Do not use this heater in areas where excessive dust exists. 
Do not touch or obstruct the grille areas when the heater is in operation.  
 
 
Introduction 
This heater has been designed for fitting in the space behind the plinth of floor standing kitchen units or other fitted furniture 
units.  It is recommended that the heater is not installed under cupboards used for storing perishable goods.  It can be 
accommodated in plinths with a minimum height of 12Omm, and is suitable for cupboards of 500mm width and above. 
 
 
Installation 
The installation of this appliance should be carried out by a competent electrician and be in accordance with the current IEE 
wiring regulations. 
Before undertaking installation work, ensure the electricity supply is disconnected from any relevant fixed wiring. 
 
The heater is more easily fitted during the installation of new furniture units, or on existing furniture units if they can be 
temporarily moved from their position against the wall.  If an existing furniture unit cannot be moved, then it may be 
necessary to remove the back of the unit in order to gain access to carry out the wiring installation. 
Before installing the unit consider the location with respect to the following; 
The electrical supply and cable length. 
Position heater to deliver heat effectively without causing personal discomfort from overheating while standing at 
work surfaces etc. 
      Minimum plinth height of 120mm and minimum furniture unit width of 500mm. 
 
 
Procedure 
 
1.  Cutting the aperture in the Plinth  
Cut aperture in furniture unit plinth to dimensions 
shown.
 
  This must be positioned so that the 
minimum distance from the bottom of the aperture 
to the TOP surface of any floor covering is not 
less than 12mm and not more than 25mm. 
 
If an overhang above the heater is greater than 
75mm, then a distance of at least 100mm must 
be maintained between the overhang and the 
uppermost part of the heater. 
 
Note:  If fitted in corner with adjacent cupboards 
to left hand side of heater then a distance of at 
least 150mm must be maintained between the left 
hand end of the heater and the front of the 
adjacent cupboard door. 
 
*
 This dimension must be maintained above the 
top surface of any floor covering material.  All 
dimensions in millimetres.