Essick Air SAS10012 User Manual

Page of 16
110526
4
Limited Warranty
This warranty is extended to the original purchaser of an evaporative cooler installed and used under normal conditions.  It does not cover damages in-
curred through accident, neglect, or abuse by the owner.  We do not authorize any person or representative to assume for us any other or different liability 
in connection with this product.
Terms And Conditions Of  The Warranty
Lifetime Limited Coverage on water reservoir against any leakage due to defects in material.  From date of purchase, if any original component part fails 
due to defect in material or factory workmanship only, we will provide the replacement part as follows:
 
One year on the cabinet components.
 
Two years on the evaporative media.
 
Exclusions From The Warranty
We are not responsible for any incidental or consequential damage resulting from any malfunction.
We are not responsible for any damage received from the use of water softeners, chemicals, de-scale material, plastic wrap, or if a motor of a higher 
horsepower than what is shown on the serial plate is used in the unit.
We are not responsible for the cost of service calls to diagnose cause of trouble, or labor charge to repair and/or replace parts.
How To Obtain Service Under This Warranty
Contact the Dealer where you purchased the evaporative cooler.  If for any reason you are not satisfi ed with the response from the dealer, contact the 
Customer Service Department:  5800 Murray Street, Little Rock, Arkansas 72209.  1-800-643-8341.  E-mail: info@championcooler.com,  Web: www.
championcooler.com.
This limited warranty applies to original purchaser only.
Failure to 
start or no air 
delivery
Inadequate 
air delivery 
with cooler 
running
Musty or 
unpleasant 
odor
1. No electrical power 
to unit
 • Fuse blown
  •  Circuit breaker tripped
2. Belt too loose or tight
3. Motor overheated
  •  Belt too tight
  •  Blower bearings dry
  •  Motor bearings dry
  •  Motor pulley diameter 
too large
4. Motor locked
1. Insuffi cient air exhaust
2. Belt too loose
3. Pads plugged
4. Insuffi cient water fl ow 
over pads
1. Stale or stagnate water 
in cooler
2. Pads not wetting 
properly
  •  Dist. tube holes 
clogged
  •  Pump not working 
properly
 • Insuffi cient water fl ow 
over pads
1. Check power
 • Replace fuse
 • Reset breaker
2. Adjust belt tension
3. Determine cause of 
overheating
  •  Adjust belt tension
  •  Grease blower bear-
ings
  •  Oil motor bearings
  •  Adjust pulley to cor-
rect diameter
4. Replace motor
1. Open windows or 
doors to increase air 
fl ow
2. Adjust belt tension or 
replace if needed
3. Clean pads
4. Clean distribution 
system
1. Drain pan and clean 
pads
2. Check water distribu-
tion system
 • Clean
  •  Replace or clean 
pump (Unplug)
  •  Clean water distribu-
tion system
1. Check voltage
2. Adjust belt tension
3. Grease or replace 
bearings (Disconnect 
unit)
4. Grease bearings
5. Adjust pulley so full 
load ampere rating of 
motor is not exceeded
6. Replace motor
1. Grease bearings
2. Inspect and realign 
(Disconnect unit)
3. Tighten loose parts
1. Open windows or 
doors to increase air 
fl ow
2. Check water distribu-
tion system
 • Clean pads
 • Clean
  •  Replace or clean 
pump (Unplug)
1. Open doors or win-
dows
Motor 
cycles on 
and off
Noisy
Inadequate 
cooling
Excessive 
humidity in 
house
1. Low voltage
2. Excessive belt tension
3. Blower shaft tight or 
locked
4. Bearings dry
5. Motor pulley diameter 
too large causing motor 
overload
6. Faulty motor
1. Bearings dry
2. Wheel rubbing blower 
housing
3. Loose parts
1. Inadequate exhaust in 
house
2. Pads not wet
 • Pads plugged
  •  Dist. tube holes 
clogged
  •  Pump not working 
properly
1. Inadequate exhaust
Problem Possible 
Cause  Remedy
Problem Possible 
Cause  Remedy
Troubleshooting Guide