Radiance Direct Vent /Natural Vent Gas Heater
20004188
The Radiance Direct Vent/Natural Vent Room Heater, Model  
Nos. 3350 thru 3354, 3360 thru 3369 and 3390 thru 3399, is a 
vented gas appliance listed to the ANSI standard Z21.88b-2002  
and CSA-2.33b-2002 for Vented Room Heaters, and  CSA 2.17-
M91, Gas-Fired Appliances For Use at High Altitudes.
The  installation  of  the  Radiance  Direct  Vent/Natural  Vent 
Room Heater must conform with local codes, or in the absence 
of local codes, with National Fuel Gas Code, ANSI Z223.1/NFPA 
54 — latest edition and CSA B-149.1  Installation Code. (EX-
CEPTION:  Do not derate this appliance for altitude.  Maintain 
the manifold pressure at 3.5 inches w.c. for Natural Gas and 
10 inches w.c. for LP gas at maximum input.) Refer to Page 
30 (RF only).
This appliance is only for use with the type of gas indicated 
on the rating plate. This appliance is not convertible for use with 
other gases unless a certified kit is used. 
Installation and replacement of gas piping, gas utiliza-
tion equipment or accessories, and repair and servicing of 
equipment shall be performed only by a qualified agency.  
The  term  “qualified  agency”  means  any  individual,  firm, 
corporation, or company that either in person or through 
a representative is engaged in and is responsible for  (a) 
installation or replacement of gas piping, or (b), the con-
nection, installation, repair, or servicing of equipment, who 
is experienced in such work, familiar with all precautions 
required, and has complied with all the requirements of the 
authority having jurisdiction.
The  Radiance  Direct  Vent/Natural  Vent  Room  Heater 
should be inspected before use and at least annually by a 
qualified service agency. It is imperative that control com-
partments, burners, and circulating air passageways of the 
appliance be kept clean.
The Radiance Direct Vent/Natural Vent Room Heater and 
its individual shut-off valve must be disconnected from the gas 
supply piping during any pressure testing of that system at test 
pressures in excess of 1/2 psig (3.5 kPa).
The Radiance Direct Vent/Natural Vent Room Heater must 
be  isolated  from  the  gas  supply  piping  system  by  closing  its 
individual manual shutoff valve during any pressure testing of 
the gas supply piping system at test pressures equal to or less 
than 1/2 psig.
An accessible tap is located above the pilot/On-Off knob for 
checking the inlet pressure.
‘Direct Vent’ describes a sealed combustion system in which 
incoming outside air for combustion and outgoing exhaust enter 
and exit through two separate concentric passages within the 
same sealed vent system. The system does not use room air 
to  support  combustion.  The  Direct  Vent  system  permits  the 
gas appliance to be vented directly to the outside atmosphere 
through  the  side  of  the  house  or  vertically  through  the  roof. 
Conventional venting systems (Natural Vent) take air from the 
room for combustion and vent the exhaust vertically through the 
roof to the atmosphere.
This appliance is approved for bedroom installations in the 
U.S. and Canada. Check local codes for natural vent require-
ments.
This appliance may be installed in an aftermarket* manu-
factured (mobile) home, where not prohibited by state or local 
codes. 
WARNING: Operation of this heater when not connected 
to a properly installed and maintained venting system can 
result  in  carbon  monoxide  (CO)  poisoning  and  possible 
death.
The Radiance Direct Vent/Natural Vent Room Heater, when 
installed, must be electrically grounded in accordance with lo-
cal codes or, in the absence of local codes, with the National 
Electrical Code ANSI/NFPA 70, (latest edition), or of the current 
Canadian Electrical Code C22.1.
Due to high temperatures this appliance should be located 
out of traffic and away from furniture and draperies.
WARNING:  This appliance is hot while in operation.  Keep 
children, clothing, and furniture away.  Contact may cause 
burns or ignition of combustible materials.
Children and adults should be alerted to the hazards of 
high surface temperatures and should stay away to avoid 
burns or clothing ignition. Young children should be care-
fully  supervised  when  they  are  in  the  same  room  as  the 
appliance.
Clothing  or  other  flammable  materials  should  not  be 
placed on or near the appliance. 
Any safety screen, glass or guard removed for servic-
ing an appliance must be replaced prior to operating the 
appliance.
The  appliance  area  must  be  kept  clear  and  free  from 
combustible materials, gasoline, and other flammable va-
pors and liquids.
The flow of combustion and ventilation air must not be 
obstructed. The installation must include adequate acces-
sibility and clearance for servicing and proper operation.
WARNING:    Do  not  operate  the  Room  Heater  with  the 
glass panel removed, cracked or broken. Replacement of 
the panel should be done by a licensed or qualified service 
person.
Do not use this appliance if any part has been under water. 
Immediately call a qualified service technician to inspect the 
appliance and to replace any part of the control system and 
any gas control which has been under water.
Do not burn wood, trash or any other material for which 
this appliance was not designed. This appliance is designed 
to burn either natural gas or propane only.
This gas appliance must not be connected to a chimney 
flue serving a separate solid-fuel burning appliance.
CAUTION: Label all wires prior to disconnection when 
servicing controls. Wiring errors can cause improper and 
dangerous operation.
Verify proper operation after servicing.
*
 
Aftermarket:   Completion of sale, nor for purpose of resale, 
from the manufacturer.
Installation & Operating Instructions
Proposition 65 Warning: Fuels used in gas, woodburning 
or oil fired appliances, and the products of combustion of 
such fuels, contain chemicals known to the State of Cali-
fornia to cause cancer, birth defects and other reproductive 
harm.