Trane 2TTA3030A3000A User Manual

Page of 48
22-1770-01-1205 (EN)
31
CORRECTION FACTORS FOR OTHER COMBINATIONS (MULTIPLY DATA BY FACTOR)
MBTUH MBTUH SYST
INDOOR MODEL
CFM
TOT
SEN
KW
CORRECTION FACTORS FOR OTHER COMBINATIONS (MULTIPLY DATA BY FACTOR)
MBTUH MBTUH SYST
INDOOR MODEL
CFM
TOT
SEN
KW
Performance Data
Cooling
TXH041A4+TYATXV-3+*UD060R9V3
NOMINAL
1200
1.00
1.00
1.00
LOW
1059
0.98
0.98
0.99
HIGH
1361
1.02
1.02
1.01
TXH041A4+TYATXV-3+*UD080R9V3
NOMINAL
1200
1.00
1.00
1.00
LOW
1050
0.98
0.98
0.99
HIGH
1350
1.02
1.02
1.01
TXH041A4+TYATXV-3+*UD080R9V4
NOMINAL
1200
1.00
1.00
1.00
LOW
1033
0.98
0.98
0.99
HIGH
1328
1.02
1.02
1.01
TXH041A4+TYATXV-3+*UD100R9V3
NOMINAL
1200
1.00
1.00
1.00
LOW
1076
0.98
0.98
0.99
HIGH
1384
1.02
1.02
1.01
2TTA3036A3/4
TXH041A4+TYATXV-3+*UD100R9V5
NOMINAL
1200
1.00
1.00
1.00
LOW
1059
0.98
0.98
0.99
HIGH
1361
1.02
1.02
1.01
TXH041A4+TYATXV-3+*UY060R9V3
NOMINAL
1200
1.00
1.00
1.00
LOW
928
0.98
0.98
0.99
HIGH
1193
1.02
1.02
1.01
TXH041A4+TYATXV-3+*UY080R9V3
NOMINAL
1200
1.00
1.00
1.00
LOW
901
0.98
0.98
0.99
HIGH
1159
1.02
1.02
1.01
2TTA3042A3/4
2TTA3042A3/4 WITH 2TXCB042AC3 AT 1199 CFM
O.D.
I.D.
TOT.
SENS. CAP. AT ENTERING D.B. TEMP.
TOTAL
D.B.
W.B.
CAP.
72
75
78
80
KW
59
36.8
22.6
27.2
31.7
34.7
3.06
85
63
38.3
20.7
24.9
29.1
31.8
3.08
67
41.3
17.9
21.5
25.1
27.4
3.13
71
44.6
14.8
17.9
20.8
22.8
3.16
59
34.7
21.8
26.2
30.6
33.4
3.29
95
63
36.1
20.0
24.1
28.1
30.7
3.31
67
39.0
17.3
20.8
24.2
26.5
3.36
71
42.1
14.3
17.2
20.1
22.0
3.39
59
32.6
21.0
25.2
29.4
32.1
3.51
105
63
34.0
19.2
23.1
27.0
29.5
3.54
67
36.6
16.6
20.0
23.3
25.4
3.60
71
39.5
13.8
16.6
19.3
21.1
3.63
59
30.5
20.1
24.1
28.1
30.5
3.74
115
63
31.8
18.4
22.1
25.8
28.2
3.77
67
34.3
15.9
19.1
22.3
24.3
3.83
71
37.0
13.2
15.8
18.5
20.2
3.86
CORRECTION FACTORS FOR OTHER AIRFLOWS (MULTIPLY DATA BY FACTOR)
AIRFLOW
TOTAL CAPACITY
SENSIBLE CAPACITY
LOW
1049
0.98
0.98
HIGH
1349
1.02
1.02
NOTE: ALL TABLES ABOVE ARE AT ARI RATING CONDITIONS RATED WITH 25 FEET OF REFRIGERANT LINES.
* DRY COIL CONDITION (TOTAL CAPACITY = SENSIBLE CAPACITY)
TOTAL CAPACITY, COMP. KW AND APP. DEW PT. ARE VALID ONLY FOR WET COIL. ALL TEMPERATURES IN DEGREES F.
CORRECTION FACTORS FOR OTHER COMBINATIONS (MULTIPLY DATA BY FACTOR)
MBTUH MBTUH SYST
INDOOR MODEL
CFM
TOT
SEN
KW
2CXAB042AC3
NOMINAL
1199
1.00
1.00
1.00
LOW
1094
0.98
0.98
0.99
HIGH
1406
1.02
1.02
1.01
2CXAB042AC3+*UD080R9V4
NOMINAL
1199
1.00
1.00
1.00
LOW
1225
0.98
0.98
0.99
HIGH
1575
1.02
1.02
1.01
2CXAB048AC3
NOMINAL
1199
1.00
1.00
1.00
LOW
1068
0.98
0.98
0.99
HIGH
1373
1.02
1.02
1.01
CORRECTION FACTORS FOR OTHER COMBINATIONS (MULTIPLY DATA BY FACTOR)
MBTUH MBTUH SYST
INDOOR MODEL
CFM
TOT
SEN
KW
2CXAB048AC3+*UD080R9V4
NOMINAL
1199
1.00
1.00
1.00
LOW
1225
0.98
0.98
0.99
HIGH
1575
1.02
1.02
1.01
2CXAC043AC3
NOMINAL
1199
1.00
1.00
1.00
LOW
1225
0.98
0.98
0.99
HIGH
1575
1.02
1.02
1.01
2CXAC043AC3+*DY100R9V4
NOMINAL
1199
1.00
1.00
1.00
LOW
1076
0.98
0.98
0.99
HIGH
1384
1.02
1.02
1.01
2CXAC043AC3+*UY100R9V4
NOMINAL
1199
1.00
1.00
1.00
LOW
1068
0.98
0.98
0.99
HIGH
1373
1.02
1.02
1.01
2CXAC049AC3
NOMINAL
1199
1.00
1.00
1.00
LOW
1225
0.98
0.98
0.99
HIGH
1575
1.02
1.02
1.01
2CXAC049AC3+*DY100R9V4
NOMINAL
1199
1.00
1.00
1.00
LOW
1076
0.98
0.98
0.99
HIGH
1384
1.02
1.02
1.01
2CXAC049AC3+*UY100R9V4
NOMINAL
1199
1.00
1.00
1.00
LOW
1068
0.98
0.98
0.99
HIGH
1373
1.02
1.02
1.01
2CXAD050AC3
NOMINAL
1199
1.00
1.00
1.00
LOW
1225
0.98
0.98
0.99
HIGH
1575
1.02
1.02
1.01
2CXAD050AC3+*DD120R9V5
NOMINAL
1199
1.00
1.00
1.00
LOW
1234
0.98
0.98
0.99
HIGH
1586
1.02
1.02
1.01
2CXAD050AC3+*DY120R9V5
NOMINAL
1199
1.00
1.00
1.00
LOW
1068
0.98
0.98
0.99
HIGH
1373
1.02
1.02
1.01
2CXAD050AC3+*UD120R9V5
NOMINAL
1199
1.00
1.00
1.00
LOW
1216
0.98
0.98
0.99
HIGH
1564
1.02
1.02
1.01
2CXAD050AC3+*UD140R9V5
NOMINAL
1199
1.00
1.00
1.00
LOW
1208
0.98
0.98
0.99
HIGH
1553
1.02
1.02
1.01
2CXAD050AC3+*UY120R9V5
NOMINAL
1199
1.00
1.00
1.00
LOW
1059
0.98
0.98
0.99
HIGH
1361
1.02
1.02
1.01