Trane 2TTA3030A3000A User Manual

Page of 48
36
22-1770-01-1205 (EN)
CORRECTION FACTORS FOR OTHER COMBINATIONS (MULTIPLY DATA BY FACTOR)
MBTUH MBTUH SYST
INDOOR MODEL
CFM
TOT
SEN
KW
CORRECTION FACTORS FOR OTHER COMBINATIONS (MULTIPLY DATA BY FACTOR)
MBTUH MBTUH SYST
INDOOR MODEL
CFM
TOT
SEN
KW
Performance Data
Cooling
TXH054A4+TYATXV-3+*UD080R9V3
NOMINAL
1199
1.00
1.00
1.00
LOW
1243
0.98
0.98
0.99
HIGH
1598
1.02
1.02
1.01
TXH054A4+TYATXV-3+*UD080R9V4
NOMINAL
1199
1.00
1.00
1.00
LOW
1225
0.98
0.98
0.99
HIGH
1575
1.02
1.02
1.01
TXH054A4+TYATXV-3+*UD100R9V5
NOMINAL
1199
1.00
1.00
1.00
LOW
1286
0.98
0.98
0.99
HIGH
1654
1.02
1.02
1.01
TXH054A4+TYATXV-3+*UD120R9V5
NOMINAL
1199
1.00
1.00
1.00
LOW
1234
0.98
0.98
0.99
HIGH
1586
1.02
1.02
1.01
TXH054A4+TYATXV-3+*UD140R9V5
NOMINAL
1199
1.00
1.00
1.00
LOW
1216
0.98
0.98
0.99
HIGH
1564
1.02
1.02
1.01
TXH054A4+TYATXV-3+*UY080R9V3
NOMINAL
1199
1.00
1.00
1.00
LOW
1068
0.98
0.98
0.99
HIGH
1373
1.02
1.02
1.01
TXH054A4+TYATXV-3+*UY100R9V4
NOMINAL
1199
1.00
1.00
1.00
LOW
1076
0.98
0.98
0.99
HIGH
1384
1.02
1.02
1.01
TXH054A4+TYATXV-3+*UY120R9V5
NOMINAL
1199
1.00
1.00
1.00
LOW
1059
0.98
0.98
0.99
HIGH
1361
1.02
1.02
1.01
TXH063P3
NOMINAL
1199
1.00
1.00
1.00
LOW
1225
0.98
0.98
0.99
HIGH
1575
1.02
1.02
1.01
TXH063P3+*DD080R9V3
NOMINAL
1199
1.00
1.00
1.00
LOW
1173
0.98
0.98
0.99
HIGH
1508
1.02
1.02
1.01
TXH063P3+*DD100R9V5
NOMINAL
1199
1.00
1.00
1.00
LOW
1234
0.98
0.98
0.99
HIGH
1586
1.02
1.02
1.01
2TTA3042A3/4
TXH063P3+*DD120R9V5
NOMINAL
1199
1.00
1.00
1.00
LOW
1234
0.98
0.98
0.99
HIGH
1586
1.02
1.02
1.01
TXH063P3+*DY100R9V4
NOMINAL
1199
1.00
1.00
1.00
LOW
1076
0.98
0.98
0.99
HIGH
1384
1.02
1.02
1.01
TXH063P3+*DY120R9V5
NOMINAL
1199
1.00
1.00
1.00
LOW
1068
0.98
0.98
0.99
HIGH
1373
1.02
1.02
1.01
TXH063P3+*UD080R9V3
NOMINAL
1199
1.00
1.00
1.00
LOW
1243
0.98
0.98
0.99
HIGH
1598
1.02
1.02
1.01
TXH063P3+*UD100R9V5
NOMINAL
1199
1.00
1.00
1.00
LOW
1278
0.98
0.98
0.99
HIGH
1643
1.02
1.02
1.01
TXH063P3+*UD120R9V5
NOMINAL
1199
1.00
1.00
1.00
LOW
1225
0.98
0.98
0.99
HIGH
1575
1.02
1.02
1.01
TXH063P3+*UD140R9V5
NOMINAL
1199
1.00
1.00
1.00
LOW
1208
0.98
0.98
0.99
HIGH
1553
1.02
1.02
1.01
TXH063P3+*UY080R9V3
NOMINAL
1199
1.00
1.00
1.00
LOW
1059
0.98
0.98
0.99
HIGH
1361
1.02
1.02
1.01
TXH063P3+*UY100R9V4
NOMINAL
1199
1.00
1.00
1.00
LOW
1068
0.98
0.98
0.99
HIGH
1373
1.02
1.02
1.01
TXH063P3+*UY120R9V5
NOMINAL
1199
1.00
1.00
1.00
LOW
1059
0.98
0.98
0.99
HIGH
1361
1.02
1.02
1.01
2TTA3048A3/4
2TTA3048A3/4 WITH 2TXCC049AC3 AT 1600 CFM
O.D.
I.D.
TOT.
SENS. CAP. AT ENTERING D.B. TEMP.
TOTAL
D.B.
W.B.
CAP.
72
75
78
80
KW
59
43.1
27.7
33.3
38.9
42.5
3.65
85
63
44.9
25.4
30.6
35.6
39.0
3.67
67
48.4
21.9
26.4
30.8
33.6
3.73
71
52.3
18.2
21.9
25.5
27.9
3.77
59
40.9
26.9
32.3
37.7
40.9
3.94
95
63
42.6
24.7
29.7
34.6
37.8
3.97
67
46.0
21.3
25.6
29.8
32.6
4.04
71
49.6
17.7
21.2
24.7
27.1
4.07
59
38.7
26.0
31.3
36.4
38.7
4.24
105
63
40.4
23.8
28.7
33.4
36.5
4.27
67
43.5
20.6
24.7
28.8
31.5
4.34
71
47.0
17.1
20.5
23.9
26.2
4.38
59
36.5
25.0
30.1
35.1
36.5
4.53
115
63
38.1
23.0
27.6
32.2
35.2
4.56
67
41.0
19.8
23.8
27.8
30.4
4.64
71
44.3
16.4
19.8
23.0
25.2
4.68
CORRECTION FACTORS FOR OTHER AIRFLOWS (MULTIPLY DATA BY FACTOR)
AIRFLOW
TOTAL CAPACITY
SENSIBLE CAPACITY
LOW
1400
0.98
0.98
HIGH
1800
1.02
1.02
NOTE: ALL TABLES ABOVE ARE AT ARI RATING CONDITIONS RATED WITH 25 FEET OF REFRIGERANT LINES.
* DRY COIL CONDITION (TOTAL CAPACITY = SENSIBLE CAPACITY)
TOTAL CAPACITY, COMP. KW AND APP. DEW PT. ARE VALID ONLY FOR WET COIL. ALL TEMPERATURES IN DEGREES F.
CORRECTION FACTORS FOR OTHER COMBINATIONS (MULTIPLY DATA BY FACTOR)
MBTUH MBTUH SYST
INDOOR MODEL
CFM
TOT
SEN
KW
2CXAB048AC3
NOMINAL
1600
1.00
1.00
1.00
LOW
1068
0.98
0.98
0.99
HIGH
1373
1.02
1.02
1.01
2CXAB048AC3+*UD080R9V4
NOMINAL
1600
1.00
1.00
1.00
LOW
1391
0.98
0.98
0.99
HIGH
1789
1.02
1.02
1.01
2CXAC049AC3
NOMINAL
1600
1.00
1.00
1.00
LOW
1400
0.98
0.98
0.99
HIGH
1800
1.02
1.02
1.01