Trane 2TTA3030A3000A User Manual

Page of 48
22-1770-01-1205 (EN)
5
General
Data
Product Specifications
Model No. 1
2TTA3042A3000B
2TTA3042A4000B
2TTA3048A3000A
2TTA3048A4000A
Electrical Data V/Ph/Hz 
2
200/230/3/60
460/3/60
200/230/3/60
460/3/60
Min Cir Ampacity
13
7
16
9
Max Fuse Size (Amps)
20
15
25
15
Compressor
CLIMATUF
®
CLIMATUFF
®
CLIMATUFF
®
CLIMATUFF
®
RL Amps - LR Amps
9.6 - 86.6
5.1 - 43.1
11.6 - 100.1
6.4 - 49.8
Outdoor Fan FL Amps
1.4
0.7
1.4
0.7
Fan HP
1/6
1/6
1/6
1/6
Fan Dia (inches)
27.6
27.6
27.6
27.6
Coil
Spine Fin™
Spine Fin™
Spine Fin™
Spine Fin™
Refrigerant R-22
6/13-LB/OZ
6/13-LB/OZ
8/14-LB/OZ
8/14-LB/OZ
Line Size - (in.) O.D. Gas 
3
7/8
7/8
1-1/8
1-1/8
Line Size - (in.) O.D. Liquid 
3
3/8
3/8
3/8
3/8
Dimensions H x W x D (Crated)
38.4 x 35.1 x 38.7
38.4 x 35.1 x 38.7
46.4 x 35.1 x 38.7
46.4 x 35.1 x 38.7
Weight - Shipping
245
246
303
305
Weight - Net
211
213
267
269
Start Components
NO
NO
NO
NO
Sound Enclosure
NO
NO
NO
NO
Compressor Sump Heat
YES
YES
YES
YES
Optional Accessories:
 
4
Anti-short Cycle Timer
TAYASCT501A
TAYASCT501A
TAYASCT501A
TAYASCT501A
Evaporator Defrost Control A/C
AY28X079
AY28X079
AY28X079
AY28X079
Rubber Isolator Kit
BAYISLT101
BAYISLT101
BAYISLT101
BAYISLT101
Crankcase Heater Kit
BAYCCHT300
BAYCCHT300
Extreme Condition Mounting Kit
BAYECMT001
BAYECMT001
BAYECMT001
BAYECMT001
Seacoast Kit
BAYSEAC001
BAYSEAC001
BAYSEAC001
BAYSEAC001
Refrigerant Lineset 
5
TAYREFLN3*
TAYREFLN3*
TAYREFLN4*
TAYREFLN4*
SPLIT SYSTEM
ARI Standard Capacity Rating Conditions
ARI STANDARD 210/240 RATING CONDITIONS 
(A) Cooling 80°F DB, 67°F WB air entering indoor coil,
95°F DB air entering outdoor coil.
(B) High Temperature Heating 47°F DB, 43°F WB air entering
outdoor coil, 70°F DB air entering indoor coil.
(C) Low Temperature Heating 17°F DB, 15°F WB air entering
outdoor coil, 70°F DB air entering indoor coil.
(D) Rated indoor airflow for heating is the same as for cooling.
ARI STANDARD 270 RATING CONDITIONS — (Noise rating
numbers are determined with the unit in cooling operation.)
Standard Noise Rating number is at 95°F outdoor air.
Accessory Description and Usage
Anti-Short Cycle Timer — Solid state timing device that
prevents compressor recycling until 5 minutes have elapsed
after satisfying call or power interruptions. Use in area with
questionable power delivery, commercial applications, long
lineset, etc.
Evaporator Defrost Control — SPST Temperature actu-
ated switch that cycles the condenser off as indoor coil
reaches freeze-up conditions. Used for low ambient cooling
to 30°F with TXV.
Rubber Isolators — 5 large rubber donuts to isolate
condensing unit from transmitting energy into mounting
frame or pad. Use on any application where sound transmis-
sion needs to be minimized.
Hard Start kit — Start capacitor and relay to assist compressor
motor startup. Use in areas with marginal power supply, on
long linesets, low ambient conditions, etc.
Extreme Condition Mount Kit — Bracket kits to securely mount
condensing unit to a frame or pad without removing any panels.
Use in areas with high winds, or on commercial roof tops, etc.