Rinnai EX22C (RHFE-559FTA) User Manual

Page of 84
 
Rinnai Corporation EX17C / EX22C Manual 
 
 
EX17C EX22C 
Application 
For manufactured home (USA only) or mobile home or residential installation convertible 
for use with natural gas and liquefied petroleum gases (propane / LPG) when provision is 
made for the simple conversion from one gas to the other. 
For commercial setting. 
For installation at altitudes up to 10,200 feet (3109 m).  
General Description  Forced combustion, forced convection, flued gas furnace  
Operation 
Push button electronic  
Gas Connection 
1/2 in male NPT   
Gas Control 
Electronic  
Burners 
Stainless steel Bunsen burner  
Temperature Control  Electronic thermostat, (Low, 60-80ºF in 2ºF increments, High) 
Ignition System 
Electronic spark ignition  
Flue System 
The flue must be terminated to atmosphere with only flue components listed with the 
appliance’s certification.  Warranty will be voided if non listed components are installed.  
Humidifier Tray 
Capacity - 2.1 pints (1000 cc)   
Electrical Connection  AC 120V, 60 Hz, 46 watts 
AC 120V, 60 Hz, 56 watts  
Standby Power 
0.5 watt  
Weight 
Noise Level 
33-38 dB 
33-42 dB  
AFUE Rating 
Natural Gas: 81%          Propane: 82% 
Natural Gas: 80%          Propane: 82% 
57 lbs (26 kg)  
Specifications 
Rinnai is continually updating and improving products.  Therefore, specifications are subject to change without 
prior notice. 
The efficiency rating of this appliance is a product thermal efficiency rating determined under continuous operating 
conditions and was determined independently of any installed system. 
  Safety Features 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
•  Overheat:  The appliance will automatically shut 
down when the appliance exceeds a predetermined 
temperature. 
•  Flame Failure:  The appliance will automatically 
shut down if the burner flame is extinguished. 
•  Power Failure:  The appliance will shut off the gas 
if it loses electrical power. 
•  Power Surge Fuse:  A glass fuse on the PC board 
protects against overcurrent.  If the fuse blows then 
all indicator lamps will be off. 
•  Spark Detector:  The appliance automatically 
shuts down if there is an abnormal spark at ignition. 
•  Fusible Link:  In case the overheat feature does 
not prevent an overheat then the fusible link could 
break, shutting off the appliance. 
  Appliance Specifications